+44 2080 043 608
info@labtron.co
Home
Thermal Cycler
Lab Equipment
Analytical Instruments
Catalogs
About Us
Contact Us
Request A Quote
Company Info
Terms of Use
Policies
Site map
Home
Lab Equipment
Petroleum Testing
Amino Acid Analyzer
Autoclaves
Baths and Circulators
Cabinets
Centrifuge
Freezers
Freeze Dryers
Fume Hood
Muffle Furnace
Tube Furnace
Ice Makers
Incubator
Kjeldahl Systems
Laboratory Shakers and Mixers
Oven
Peristaltic Pump
Refrigerators
Spectrophotometer
Test Chamber
Thermal Cycler
Ultrasonic Cleaner
Vacuum Pump
CO2 Incubator
Thermo-Shakers
Water Purification System
Viscometer
Oven Incubator
Flame Photometer
Microplate Reader & Washer
Petroleum Testing
Solar Powered Products
Chillers
Chromatography
HPLC
Particle Size Analyzer
Gel Documentation
TOC Analyzer
Rotary Evaporator
Polarimeter
Lab Refrigerator-Freezer Combination
Spectrometer
Microscope
Colorimeters
Testing Instruments
Colony Counter
IR Carbon Sulphur Analyzer
Sample Concentrator
Safety Containment Cabinets
Water Testing
Magnetic Stirrers and Hotplates
Microtome
Nucleic Acid Purification System
Moisture Analyzer
Oil And Grease Analyzer
UV Pass Box
Pharmaceutical Testing
V-shell Blender
Differential Thermal Analyzers
Balances
Blood Collection Monitor
Particle Counter
Density Meter
Biochemistry Analyzer
Automatic Glassware Washer
Ultrasonic Homogenizer
Environmental Monitoring Equipments
Refractometer
Water Distillers
Stomacher
Airborne Particle Counters
Hybridization Oven
Platelet Agitator and Incubator
Jar Testers
Electrophoresis System
Milk Analyzers
Potentiometric Titrator
Flammability Tester
Pathology Workstation
BLOOD THAW MACHINE
Opacity Meter
Plasma Extractor
Elemental Analyzer
Plate Sealer
Dosimeter
Stroboscope
Latex Stability Tester
Drug Detector
Wind Meter (Anemometer)
Slide Dryer
Paraffin Trimmer
Vacuum Spin Coater
Ball Mill Machine
Osmometer
ESR Analyzer
Differential Scanning Calorimeters
Water Purifier
Dehumidifier
Vacuum Pycnometer
Gene Electroporator
Laminar Flow Canopy
Fume Extractor
Heating Mantle
Gel Strength Test System
Melting Point Apparatus
Vacuum Filtration Unit
Bottle Top Dispenser
Tachometer
Hydrogen Peroxide Generator
Microwave Digestion System
Sound Level Analysis
X-Ray Machine
Fiber Analysis
Fluorometer
Hybridization System
Semi-automatic Bio-chemistry Analyzer
Soxhlet Apparatus
Color Assessment Cabinet
Leather Softness Tester
Washer Disinfector
Vacuum Packing machine
Glassware Drying Cabinet
Metal Detector
Alloy Analyzer
Blood Bag Tube Sealer
Handheld Homogenizer
Fluorescence Analyzer
Air Permeability Tester
Media Dispensing System
Laser Theodolite
Scintillation Counter
Dispersion Machine
UV Air Sterilizer
Petroleum Testing
Ash Content Tester
Existent Gum Tester
Engler Viscometer
Foaming Characteristics Tester
Mercaptan Sulfur Tester
Automatic Bomb Calorimeter
Octane Number & Cetane Number Tester
Acid and Alkali Tester
Aniline Test Equipment
Closed Cup Flash Point Tester
Demulsibility Characteristics Tester
Density Tester
Distillation Tester
Dropping Point Tester
Kinematics Viscometer
Low Temperature Tester
Open Cup Flash Point Tester
Other Instrument
Oxidation Stability Tester
Oxygen Bomb Calorimeter
Residue Carbon
Rotational Viscometer
Rust and Corrosion Tester
Sulphur Content Tester
Vapor Pressure
Water Content Tester
Automatic Tag Closed Flash Point Tester
Constant Temperature Needle Penetration Tester
No cards available for this subcategory.
No cards available for this subcategory.
No cards available for this subcategory.
No cards available for this subcategory.
No cards available for this subcategory.
Automatic Bomb Calorimeter LABC-A10
Calorimeter type:
Isoperibol
Temperature range:
5 to 40°C
Measurement range:
5 to 40 MJ/ kg
Operation Mode:
The outer barrel temperature is constant
Add to compare
Catalog
Automatic Bomb Calorimeter LABC-A11
Calorimeter type:
Isoperibol
Temperature range:
5 to 40°C
Measurement range:
5 to 40 MJ/ kg
Operation Mode:
A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode
Add to compare
Catalog
Automatic Bomb Calorimeter LABC-B10
Calorimeter type:
Isoperibol
Oxygen filling:
Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
Bomb volume:
250 ml
Analysis time:
< 8 min full test process: <10 min
Add to compare
Catalog
Automatic Bomb Calorimeter LABC-B11
Calorimeter type:
Isoperibol
Oxygen filling:
Semi-automatic
Bomb volume:
282 ml
Analysis time:
15 to 25 min
Add to compare
Catalog
Octane Number and Cetane Number Tester LOCT-A10
Measuring Range For Aviation Gasoline:
86.0 to 105.0/MON
Measuring Range For Gasoline For Motor Vehicles:
National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON
Measuring Range For Ethanol:
E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON
Measuring Range For Automobile Diesel Fuels:
Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI
Add to compare
Catalog
Portable Octane Number and Cetane Meter LOCT-A20
Measurement item:
motor gasoline and diesel
measurement unit of octane is ON:
40 to 120
Permissible error of octane:
± 0.5 max
Fluctuate range of octane:
± 0.2 max
Add to compare
Catalog
Acid Number and Acidity Tester LAAT-A11
Ambient temperature:
≤ 35 °C
Relative humidity:
≤ 85 %
Precision of titration tube:
Scale division is 0.02 ml
Total power consumption:
≤ 1200 W
Add to compare
Catalog
Acid Number Tester LAAT-A12
Measurement range:
≥0.05 mg KOH/g
Potential measurement range:
0 to 1800.0 mV
Burette volume:
10 mL
Minimum titration volume:
0.001 ml
Add to compare
Catalog
Base Number Tester LAAT-A13
Volumetric analysis:
Titration condensation: 0.1 N;<br> Controlling accuracy: ≤ ± 0.02 ml
Automatic acid titration:
Titration condensation: 0.1 N;<br> Controlling accuracy: ≤ ± 0.1 pH
Automatic potential control:
Titration condensation: 0.1 N;<br> Controlling accuracy: ≤ 10 mV
Ambient temperature:
0 ~ 35 ℃
Add to compare
Catalog
Water Soluble Acid and Alkali Tester LAAT-A10
Graduated flask:
100 ml,50 ml
Conical flask:
100ml
Separatory funnel:
250ml
Ambient temperature:
(-10 )°C to 35 °C
Add to compare
Catalog
Aniline Point Tester LAPT-A10
Measurement range:
Room temperature ~ 150°C
Stirring speed:
0 ~ 1200 r / min
Heating power:
25 W
Interior Dimension:
360 × 250 × 545 mm
Add to compare
Catalog
Aniline Point Tester LAPT-A11
Temperature controlling accuracy:
≤ 0.5 ℃
Temperature controlling range:
Room temperature ~ 200 ℃
Power supply for illumination:
5 V
Power of motor:
2 kW
Add to compare
Catalog
Automatic PMCC Flash Point Tester LCFP-A11
Ambient temperature:
10 °C ~ 40 °C
Relative humidity:
≤ 80 %
Measurement Range:
Ambient Temperature ~ 250 °C
Flash Point:
Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C
Add to compare
Catalog
Automatic PMCC Flash Point Tester LCFP-A13
Ambient temperature:
10 °C ~ 40 ℃
Relative humidity:
≤ 80 %
Ignition Mode:
electron igniter / gas flame
Temperature range:
Room Temperature ~ 300 ℃
Add to compare
Catalog
PMCC Flash Point Tester LCFP-A10
Ambient temperature:
≤ 35 °C
Relative humidity:
≤ 85 %
Temperature range:
5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C
Aperture of ignition device:
0.8 mm
Add to compare
Catalog
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10
Ambient temperature:
Room temperature to 35 °C
Relative humidity:
≤ 85 %
Timing range:
1 s to 9 min 59 s
Temperature controlling range:
Room temperature to 99.9 °C
Add to compare
Catalog
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11
Ambient temperature:
Room temperature to 35 °C
Relative humidity:
≤ 85 %
Temperature controlling range:
Room temperature to 99.9 °C
Temperature controlling accuracy:
± 1 °C
Add to compare
Catalog
Density Tester LDMT-A10
Cubage of bath:
Ф300 × 380 mm
Temperature controlling range:
0 °C ~ 100 °C
Temperature controlling accuracy:
± 0.2 °C
Temperature sensor:
Industrial platinum resistance, Pt100
Add to compare
Catalog
Automatic Distillation Apparatus LADA-A10
Heating power:
2 kW
Cooling power:
0.5 kW
Steam temperature:
0 to 400℃
Oven temperature:
0 to 500℃
Add to compare
Catalog
Benzene Distillation Tester (Low Temperature) LDT-A11
Ambient temperature:
-10°C to 35°C
Relative humidity:
≤ 85 %
Thermometer:
Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Scale division:
0.1 ℃
Add to compare
Catalog
Distillation Tester (low temperature Double units) LDT-A16
Graduated flasks:
100 ml
Distillation flask:
125 ml
Ambient temperature:
≤ 35 °C
Relative humidity:
≤ 85 %
Add to compare
Catalog
Distillation Tester (low temperature single unit) LDT-A17
Graduated flasks:
100 ml
Distillation flask:
125 mL
Ambient temperature:
≤ 30 °C
Relative humidity:
≤ 85 %
Add to compare
Catalog
Distillation Tester Dual Units LDT-A15
Graduated flasks:
100 ml
Scale division of graduated flask:
1ml
Distillation flask:
125 ml
Ambient temperature:
≤ 35 °C
Add to compare
Catalog
Distillation Tester Front Type LDT-A14
Distillation flask:
125 mL
Ambient temperature:
Room temperature to 35 °C
Relative humidity:
≤ 85 %
Thermometer:
(-2 )°C to 300 ℃ and (-2) °C to 400 ℃
Add to compare
Catalog
Distillation Tester LDT-A10
Graduated flasks:
10 ml and 100 ml
Scale division of graduated flask:
10 ml is 0.1 ml and 100 ml is 1 ml
Ambient temperature:
(-10) °C ~ 35 °C
Relative humidity:
≤ 85 %
Add to compare
Catalog
Distillation Tester LDT-A12
Graduated flasks:
100 ml
Scale division of graduated flask:
1 ml
Outer diameter of distillation flask:
φ65
Refrigeration tube:
φ14
Add to compare
Catalog
Vacuum Distillation Tester LDT-A13
Ambient temperature:
5 °C to 35 ℃
Relative humidity:
≤ 85 %
Cubage of buffer vessel:
1000 ml
Max. Residual pressure:
≤ 2 mm Hg
Add to compare
Catalog
Dropping Point Tester (Air bath) LDPT-A11
Ambient temperature:
≤ 35 ℃
Relative humidity:
≤ 85 %
Heating power of electric furnace:
250 W × 2
Total power consumption:
≤ 700 W
Add to compare
Catalog
Dropping Point Tester (Oil Bath) LDPT-A10
Beaker quantity:
600 ml
Ambient temperature:
(-10) °C ~ 40 °C
Relative humidity:
≤ 85 %
Thermometer Measurement range:
(-5) °C ~ 300 °C
Add to compare
Catalog
Kinematics Viscometer LKV-A10
Ambient temperature:
15 to 35°C
Relative humidity:
≤ 85%
Capillary viscometer:
6 capillary Pinkevitch viscometer tubes
Stirring motor:
1200 rpm
Add to compare
Catalog
Kinematics Viscometer LKV-A11
Ambient temperature:
(-10) °C ~ 35 °C
Relative humidity:
≤ 85 %
Capillary viscometer:
11 pieces
Stirring motor:
6 W, 1200 rpm
Add to compare
Catalog
Kinematics Viscometer LKV-A12
Ambient temperature:
(-10) °C ~ 35 °C
Relative humidity:
≤ 85 %
Capillary viscometer:
11 pieces
Stirring motor:
6 W, 1200 rpm
Add to compare
Catalog
Kinematics Viscometer LKV-A13
Ambient temperature:
(-10) °C ~ 35 °C
Relative humidity:
≤ 85 %
Capillary viscometer:
7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
Stirring motor:
6 W, 1200 rpm
Add to compare
Catalog
Kinematics Viscometer LKV-A15
Ambient temperature:
(-10) °C ~ 35 °C
Relative humidity:
≤ 85 %
Capillary viscometer:
11 pieces
Stirring motor:
6 W, 1200 rpm
Add to compare
Catalog
Kinematics Viscometer LKV-A16
Ambient temperature:
0 ~ 40 ºC
Relative humidity:
20 ~ 90 %, RH while 40 ℃
Temperature controlling accuracy:
± 0.1 °C
Timing range:
0.0 s ~ 9999.9 s
Add to compare
Catalog
Low Temperature Kinematic Viscosity Tester LKV-A14
Ambient temperature:
≤ 30 °C
Relative humidity:
≤ 85 %
Capillary viscometer:
13 pieces
Stirring motor:
6 W, 1200 rpm
Add to compare
Catalog
Automatic Pour Point Tester LLTT-A23
Ambient temperature:
≤ 30 ℃
Refrigeration speed:
> 40 °C / 10 min
Repeatability for solidifying point:
≤ 2 °C
Repeatability for pour point:
≤ 3 °C
Add to compare
Catalog
Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12
Ambient temperature:
(-10)℃ ~ 35 ℃
Relative humidity:
≤ 85 %
Sample cup Inner diameter:
31.0 ~ 32.0 mm
Sample cup Wall thickness:
1.0 ~ 1.5 mm
Add to compare
Catalog
Freezing Point Tester LLTT-A11
Freezing point range:
-54°C to 2°C
Cold bath measurement temperature range:
-70° to 20°C
Temperature controlling accuracy:
±0.5°C
Bath liquids stirring:
Electric
Add to compare
Catalog
Multifunctional Low Temperature Tester LLTT-A16
Refrigeration system:
New-type refrigeration compressor
Controlling temperature of cold trough:
Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C
Ambient temperature:
≤ 30 ℃
Relative humidity:
≤ 85 %
Add to compare
Catalog
Pour and Cloud Point Tester LLTT-A14
Chamber quantity:
2 chambers
Chamber 01 temperature control:
Ambient to -51 ℃
Chamber 02 temperature control:
Ambient to -65 ℃
Temperature precision:
±1°C
Add to compare
Catalog
Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15
Refrigeration system:
New-type refrigeration compressor
Controlling temperature of cold trough:
Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Ambient temperature:
≤ 30 ℃
Relative humidity:
≤ 85 %
Add to compare
Catalog
Solidifying Point Constant Temperature Water Bath LLTT-A10
Capacity:
20 L
Temperature range:
Ambient +5°C to 100°C
Precision:
± 0.1℃
Stirring range:
1200 r/min
Add to compare
Catalog
Solidifying Point Tester ('-20°C +80°C') LLTT-A22
Temperature controlling accuracy:
± 0.5 °C
Refrigeration system:
New-type refrigeration compressor
Cold trough:
One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough:
Room temperature ~ (-70) °C
Add to compare
Catalog
Solidifying Point Tester (Solidifying Point and Cold Filter Plugging Point) LLTT-A21
Refrigeration system:
New-type refrigeration compressor
Cold trough:
One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough:
Room temperature ~ (-70) °C
Ambient temperature:
≤ 30 ℃
Add to compare
Catalog
Solidifying Point Tester LLTT-A13
Temperature controlling accuracy:
± 0.5 ℃
Refrigeration system:
New-type refrigeration compressor
Cold trough:
Two holes in one trough, and same temperature
Ambient temperature:
≤ 30 ℃
Add to compare
Catalog
Solidifying Point Tester LLTT-A20
Temperature controlling accuracy:
± 0.5 °C
Refrigeration system:
New-type refrigeration compressor
Cold trough:
One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough:
Room temperature ~ (-70) °C
Add to compare
Catalog
Automatic Cleveland Open Cup Flash Point Tester LOFP-A12
Ambient Temperature:
10 ℃ ~ 40 °C
Relative Humidity:
≤ 80 %
Temperature Measurement- Full Scale:
Ambient temperature to 300 °C
Temperature Measurement- Repeatability:
≤ 8 °C
Add to compare
Catalog
Automatic COC Flash & Fire Point Tester LOFP-B10
Ambient Temperature:
10 ℃ ~ 40 ℃
Relative Humidity:
≤ 85 %
Temperature Measurement- Full Scale:
Ambient temperature to ~ 400 ℃
Temperature Measurement- Repeatability:
≤ 4 ℃
Add to compare
Catalog
Cleveland Open Cup Flash Point Tester LOFP-A11
Thermometer:
6 ℃ ~ 400 ℃
Scale Division:
2 °C
Spout Aperture:
0.6 ~ 0.8 mm
Ambient Temperature:
-10 ℃ ~ 50 ℃
Add to compare
Catalog
Open Cup Flash Point Tester LOFP-A10
Thermometer:
0 ℃ ~ 360 °C
Scale Division:
1 °C
Ambient Temperature:
≤ 35 °C
Relative Humidity:
≤ 85 %
Add to compare
Catalog
Color Tester LCT-A20
Light source:
220 V, 100 W
Temperature of grinding milk white light bulb:
2750 ± 50 K
Light hole( Φ14):
26 pieces
Color comparing tube:
Φ32 mm
Add to compare
Catalog
Insulating Oil Breakdown Voltage Tester LIBT-A23
Power supply:
AC 220 V ± 5 % , 50Hz
Measurement range:
0 ~ 75 kV
Voltage rising rate:
3 kV ± 10 % / s
Distance between electrodes:
2.5 mm
Add to compare
Catalog
Mechanical Impurity Tester (Weight Method) LMIT-A21
Dimension:
390 x 260 x 590 mm
Total power consumption:
≤ 1200 W
Power supply:
AC 220 V ± 10 %, 50 Hz
Heating power of water bath:
1000 W
Add to compare
Catalog
Wax Oil Content Tester LWCT-A22
Power supply:
AC 220 V ± 10 %, 50 Hz
Temperature controlling range in water bath:
RT ~ 90 ℃ ± 5 ℃
Cooling bath temperature:
(-35) ℃ ± 1 ℃
Evaporation temperature:
35 ℃ ± 1 ℃
Add to compare
Catalog
Automatic Lubricating Oils Oxidation Stability Tester LOST-D10
Samples:
2
Oil bath cubage:
30 L
Angle between bomb and water surface:
30 °
Speed of rotary assembly:
100 ± 5 RPM
Add to compare
Catalog
Distillate Fuel Oil Oxidation Stability Tester LOST-D12
Samples:
8
Temperature:
100 ℃
Temperature controlling accuracy:
0.1 ℃
Flow meter:
3 ± 0.3 L / H oxygen
Add to compare
Catalog
Gasoline Oxidation Stability Tester LOST-D13
Type:
Compact; Desktop
Design:
Integrated
Bath:
Metal bath (without water usage)
Temperature control point of metal bath:
100℃ ± 1℃
Add to compare
Catalog
Oxidation Stability Tester (Lubricating Grease) LOST-D20
Temperature Range:
Ambient to 150℃
Temperature Precision:
± 0.1°C
Test Unit:
2 units
Heating Power:
1800 W
Add to compare
Catalog
Transformer Oil Oxidation Stability Tester LOST-D11
Samples:
6
Temperature controlling mode:
Automatic digital temperature
Temperature controlling range:
Room temperature ~ 160 °C
Temperature controlling accuracy:
± 0.2 °C
Add to compare
Catalog
Oxygen Bomb Calorimeter LBC-C20
Heat capacity:
14000 ~ 15000 J / K
Temperature measurement range:
10 ~ 35 ℃
Repeatability error:
≤ 0.2 % (Grade C)
Endured pressure in oxygen bomb:
20 MPa
Add to compare
Catalog
Oxygen Bomb Calorimeter LBC-C21
Temperature controlling range:
10 ℃ ~ 35 ℃
Temperature resolution:
0.001 ℃
Mean value of heat capacity:
15 kJ / K
Ambient temperature:
20 ℃ ± 5 ℃
Add to compare
Catalog
Oxygen Bomb Calorimeter LBC-C22
Temperature measurement range:
10 ~ 35 ℃
Repeatability error:
≤ 0.2 % (Grade C)
Endured pressure in oxygen bomb:
20 MPa
Operation environment temperature:
15 ~ 28 ℃
Add to compare
Catalog
Carbon Residue Tester (CONRADSON METHODS) LRCT-B10
Porcelain crucible:
30 ml
Inner iron crucible:
75 ml
Outer iron crucible:
190 ml
Burner:
Mig Burner
Add to compare
Catalog
Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11
Bath type:
Four holes with a furnace
Heating type:
Electric resistance furnace
Temperature controlling range:
0 ~ 520 °C
Temperature controlling accuracy:
± 5 °C
Add to compare
Catalog
Carbon Residue Tester (Ramsbottom) LRCT-B20
Coking furnace:
Metal furnace
Heating mode:
Electric heating
Test unit:
5 units
Temperature range:
Ambient to 550°C
Add to compare
Catalog
Rotational Viscometer LRV-A10
Viscosity measurement range:
10 ~ 2000000 MPa•s
Ambient temperature:
5 °C ~ 35 °C
Ambient humidity:
Not more than 80 %
Spindles:
Four spindles of No.1 ~ 4
Add to compare
Catalog
Copper Strip Corrosion Tester LRCT-A13
Sample hole:
4 pieces
Sample quantity:
4 to 12 pieces
Ambient temperature:
Room temperature to 35 °C
Temperature controlling range:
Room temperature to 100°C
Add to compare
Catalog
Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10
Sample hole:
2 pieces
Speed of stirring motor:
1400 rpm
Ambient temperature:
10 to 35°C
Temperature controlling range:
Room Temperature to 100°C
Add to compare
Catalog
Lubricating Oil Rust Characteristics Tester LRCT-A11
Sample hole:
4 pieces
Speed of stirring motor:
1400 rpm
Speed for sample stirring:
1000 ± 50 rpm
Ambient temperature:
Room temperature to 35°C
Add to compare
Catalog
Rust Characteristics and Corrosion Tester LRCT-A12
Sample hole:
4 pieces
Ambient temperature:
Room temperature to 35°C
Temperature controlling range:
0 to 100°C
Temperature controlling accuracy:
± 1°C
Add to compare
Catalog
Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11
Air flow rate:
Not less than 150 L / h
Max. Preset time:
99 min 59 s (100 min)
Chamber diameter of oven:
Φ22 mm
Heating power of oven:
1400 W × 2
Add to compare
Catalog
X-ray Fluorescence Sulfur in Oil Analyzer LST-A10
Sample quantity:
2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)
Measurement time:
60, 120, 240, 300, and 600 s at random
Measurement range:
7 ppm to 5 %
Repeatability:
< 0.029 (S + 0.6)
Add to compare
Catalog
Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11
Test bomb:
Two samples or a group of parallel samples
Bath temperature:
37.8 °C
Temperature controlling accuracy:
0.1 °C
Dimensions:
500 × 560 × 680 mm, 950 × 540 × 720 mm
Add to compare
Catalog
Vapor Pressure Tester (REID METHOD) LVPT-C10
Operation temperature of water bath:
RT ~ 90 °C
Temperature controlling accuracy:
± 0.1 °C
Dimensions:
550 × 520 × 102 mm
Pressure meter accuracy:
± 0.4 % kPa
Add to compare
Catalog
Coulometric Karl Fischer Titrator LWT-A30
Ambient Temperature:
10°C to 35°C
Measurement Range:
0 to 100 mg
Resolution:
0.1 µg
Max. Electrolysis Speed:
40 µg /s
Add to compare
Catalog
Coulometric Karl Fischer Titrator LWT-A31
Maximum current:
400 mA
Measurement range:
3 µg to 9999.9 µg
Resolution:
0.1 µg
Precision 1:
± 2 µg (3µg H<sub>2</sub>O to 20µg H<sub>2</sub>O)
Add to compare
Catalog
Crude Petroleum Water Content Tester LWT-B10
Ambient Temperature Range:
-10 to 35°C
Relative Humidity:
≤85%
Distillation Flask:
1000 ml
Receiver:
5 ml, with 0.05 ml graduation
Add to compare
Catalog
Water Content Tester LWT-A10
Ambient Temperature Range:
≤ 35°C
Relative Humidity:
≤ 85%
Heating Mantle Cap Power:
1000 W
Sample Determination:
1 at a time
Add to compare
Catalog
Water Content Tester LWT-A11
Ambient Temperature Range:
≤ 35°C
Relative Humidity:
≤ 85%
Heating Mantle Cap Power:
1000 W × 2
Sample Determination:
2 at a time
Add to compare
Catalog
Automatic Tag Closed Flash Point Tester LACF-A10
Experimental temperature range:
-50 to 70°C
Test sample volume:
50 ml
Ambient temperature range:
10 to 40°C
Humidity:
≤ 85%
Add to compare
Catalog
Constant Temperature Needle Penetration Tester LTNP-A10
Measuring range:
0 to 700 taper degree (digital display table 0-70 mm)
Timing device:
Timing error is less than ±0.1 s
Resolution:
0.01 mm
Needle insertion accuracy:
±1 cone insertion degree
Add to compare
Catalog
COMPARE
×