Petroleum Testing | Coulometric Karl Fischer Titrator LWT-A31

Coulometric Karl Fischer Titrator LWT-A31 is a benchtop unit with 5 to 40°C ambient temperature range, 3 µg to 9999.9 µg measurement range, and offers 400 mA maximum current. Excellent low-power operation makes it possible to compact battery, enables portable function criterion for measuring electrode signal for the electrolysis end. It stability and accuracy are key factors affecting the measurement accuracy. Designed with streamline and 5 inch coloured touch screen with standard testing method used ASTMD4928, ASTMD1533 and ASTMD6304 in titration process.

Maximum current 400 mA
Measurement range 3 µg to 9999.9 µg
Resolution 0.1 µg
Precision 1 ± 2 µg (3µg H<sub>2</sub>O to 20µg H<sub>2</sub>O)
Precision 2 ± 3 µg (20µg H<sub>2</sub>O to 100µg H<sub>2</sub>O)
Precision 3 ≤ 5 % (100µg H<sub>2</sub>O to 10mg H<sub>2</sub>O)
Data saving 496 pcs
Built-in printer Thermal printer
Calculation formula 8 kinds can be selected
Ambient temperature 5 to 40°C
Dimension 400 × 260 × 180 mm
Power consumption 50 W
Power Supply AC 220 V±10%, 50Hz ±5 %
Net weight 5 kg
  • Design with streamline and 5 inch coloured touch screen
  • Electrolytic process is intelligently control completely
  • It adopts real-time dynamic impedance method to detect the end point of titration
  • Equipped with open-circuit fault, short-circuit fault and measuring electrode
  • High-precision, and it has automatic detection function
  • Inbuilt thermal printer and end point is settable
Coulometric Karl Fischer Titrator is widely used to determine the trace water content in liquid petroleum, chemical engineering, pharmacy, electricity, scientific research and education department.

Water Content Tester

Water Content Tester LWT-A10

Water Content Tester LWT-A10

  • Ambient Temperature Range
  • ≤ 35°C
  • Relative Humidity
  • ≤ 85%
  • Heating Mantle Cap Power
  • 1000 W
Crude Petroleum Water Content Tester LWT-B10

Crude Petroleum Water Content Tester LWT-B10

  • Ambient Temperature Range
  • -10 to 35°C
  • Relative Humidity
  • ≤85%
  • Distillation Flask
  • 1000 ml
Water Content Tester LWT-A11

Water Content Tester LWT-A11

  • Ambient Temperature Range
  • ≤ 35°C
  • Relative Humidity
  • ≤ 85%
  • Heating Mantle Cap Power
  • 1000 W × 2
Coulometric Karl Fischer Titrator LWT-A30

Coulometric Karl Fischer Titrator LWT-A30

  • Ambient Temperature
  • 10°C to 35°C
  • Measurement Range
  • 0 to 100 mg
  • Resolution
  • 0.1 µg