We offer equipment for testing water to determine parameters like conductivity, dissolved oxygen, ions, BOD, pH, chlorine, water hardness, water activity, salinity, TDS, TSS, turbidity, and ORP. All our products are carefully made to provide sensitive, accurate test results and to ensure that the results can be repeated. Products employ cutting-edge technology to achieve your goal of receiving results about water that can distinguish between pure and filthy water.
Conductivity measurement range | 0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm |
Conductivity accuracy | ±1% F.S. |
Conductivity resolution | 0.001, 0.01, 0.1, 1 |
Conductivity calibration points | 1 to 3 points |
TDS measurement Range | 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) |
TDS Accuracy | ± 1 % F.S. |
TDS Factor | 0.01 to 1.00 (default 0.5) |
TDS Calibration points | 3 points |
Temperature range | 0 to 105°C, 32 to 221°F |
Temperature accuracy | ±1°C |
Temperature resolution | 0.1°C, 0.1°F |
Temperature calibration points | 1 point |
COD determination range | 2 to 10000 mg/ L |
COD measurement accuracy | COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 % |
COD minimum detection limit | 0.1 mg/ L |
COD measurement time | 20 minutes |
Ammonia nitrogen determination range | 0.02 to 60 mg/ L |
Ammonia nitrogen measurement accuracy | ≤ ± 10 % |
Ammonia nitrogen minimum detection limit | 0.01 mg/ L |
Ammonia nitrogen measurement time | 10 to 15 minutes |
Total phosphorous determination range | 0.002 to 20 mg/ L |
Total phosphorous total phosphorous measurement accuracy | ≤ ± 5 % |
Total phosphorous minimum detection limit | 0.001 mg/ L |
Total phosphorous measurement time | 35 to 50 minutes |
Turbidity determination range | 0.5 to 400 NTU |
Turbidity measurement accuracy | ≤ ± 5 % |
Turbidity minimum detection limit | 0.1 NTU |
Turbidity measurement time | 1 minute |
COD determination range | 5 to 5000 mg/ L |
COD measurement accuracy | COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 % |
COD minimum detection limit | 0.1 mg/ L |
COD measurement time | 20 minutes |
Ammonia nitrogen determination range | 0.02 to 30 mg/ L |
Ammonia nitrogen measurement accuracy | ≤ ± 10 % |
Ammonia nitrogen minimum detection limit | 0.01 mg/ L |
Ammonia nitrogen measurement time | 10 to 15 minutes |
Total phosphorous determination range | 0.002 to 10 mg/ L |
Total phosphorous total phosphorous measurement accuracy | ≤ ± 5 % |
Total phosphorous minimum detection limit | 0.001 mg/ L |
Total phosphorous measurement time | 35 to 50 minutes |
Turbidity determination range | 0.5 to 400 NTU |
Turbidity measurement accuracy | ≤ ± 5 % |
Turbidity minimum detection limit | 0.1 NTU |
Turbidity measurement time | 1 minute |
Range | 0.00 to 5.00 mg/L |
Accuracy | 0.001 mg/L 0.001 ABS |
Repeatability Lower detection limit | ≤0.02 mg/L |
Range | 0.00 to 10.00 mg/L |
Resolution | 0.001 mg/L 0.001 ABS |
Accuracy | ≤2 mg/L: ±0.10 mg/L ˃2 mg/L: ±5 % |
Lower detection limit | ≤0.04 mg/L |
Conductivity measurement range | 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm |
Conductivity accuracy | ±0.5% F.S |
Conductivity calibration points | 1 to 3 points |
Conductivity calibration solutions | 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom |
Temperature measuring range | 0 105 °C, 32 to 221 °F |
Temperature measuring accuracy | ± °0.5 C, ± 0.9 °F |
Temperature calibration points | 1 point |
Temperature resolution | 0.1 °C, 0.1 °F |
Conductivity measurement range | 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm |
Conductivity accuracy | ±0.5% F.S |
Conductivity calibration points | 1 to 5 points |
Conductivity calibration solutions | 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom |
TDS range | 0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) |
TDS accuracy | ±1 % F.S |
TDS factor | 0.01 to 1.00 (Default 0.5) |
TDS resolution | 0.01, 0.1, 1 |
Temperature measuring range | 0 105 °C, 32 to 221 °F |
Temperature measuring accuracy | ± °0.5 C, ± 0.9 °F |
Temperature calibration points | 1 point |
Temperature resolution | 0.1 °C, 0.1 °F |
Conductivity measurement range | 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm |
Conductivity accuracy | ±0.5% F.S |
Conductivity calibration points | 1 to 5 points |
Conductivity calibration solutions | 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom |
Salinity range | 0.00 to 80.00 ppt, 0.00 to 42.00 psu |
Salinity accuracy | ±1% F.S |
Salinity measurement modes | Practical Salinity (psu) or Natural Seawater (ppt) |
Salinity resolution | 0.01, 0.1, 1 |
Temperature measuring range | 0 105 °C, 32 to 221 °F |
Temperature measuring accuracy | ± °0.5 C, ± 0.9 °F |
Temperature calibration points | 1 point |
Temperature resolution | 0.1 °C, 0.1 °F |
Conductivity measurement range | 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm |
Conductivity accuracy | ±0.5% F.S |
Conductivity calibration points | 1 to 5 points |
Conductivity calibration solutions | 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom |
TDS range | 0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) |
TDS accuracy | ±1 % F.S |
TDS factor | 0.01 to 1.00 (Default 0.5) |
TDS resolution | 0.01, 0.1, 1 |
Salinity range | 0.00 to 80.00 ppt, 0.00 to 42.00 psu |
Salinity accuracy | ±1% F.S |
Salinity measurement modes | Practical Salinity (psu) or Natural Seawater (ppt) |
Salinity resolution | 0.01, 0.1, 1 |
Resistivity range | 0.00 to 20 MΩ |
Resistivity accuracy | ±1% F.S |
Resistivity resolution | 0.01, 0.1, 1 |
pH measurement range | (-2.000) to 20.000 pH |
pH accuracy | ± 0.002 pH |
pH calibration points | 1 - 5 points |
pH calibration solutions | USA, NIST, DIN or user defined |
ORP measurement range | -1999.9 to 1999.9 mV |
ORP accuracy | ±0.2 mV |
ORP calibration points | 1 point |
ORP calibration solutions | mV & relative mV |
Ion measurement range | 0 to 19999 ppm, mg/L, mol/L |
Ion accuracy | ± 0.5 % F.S. (monovalent), ± 1 % F.S. (divalent) |
Ion calibration points | 2 - 5 points |
Ion calibration solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/L, mg/L |
Conductivity measurement range | 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm |
Conductivity accuracy | ± 0.5 % F.S. |
Conductivity calibration points | 1 - 5 points |
Conductivity calibration solutions | 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm |
pH measurement range | (-2.000) to 20.000 pH |
pH accuracy | ± 0.002 pH |
pH calibration points | 1 - 5 points |
pH calibration solutions | USA, NIST, DIN or user defined |
ORP measurement range | -1999.9 to 1999.9 mV |
ORP accuracy | ±0.2 mV |
ORP calibration points | 1 point |
ORP calibration solutions | mV & relative mV |
Conductivity measurement range | 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm |
Conductivity accuracy | ± 0.5 % F.S. |
Conductivity calibration points | 1 - 5 points |
Conductivity calibration solutions | 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm |
pH measurement range | (-2.000) to 20.000 pH |
pH accuracy | ± 0.002 pH |
pH calibration points | 1 - 5 points |
pH calibration solutions | USA, NIST, DIN or user defined |
ORP measurement range | -1999.9 to 1999.9 mV |
ORP accuracy | ±0.2 mV |
ORP calibration points | 1 point |
ORP calibration solutions | mV & relative mV |
Conductivity measurement range | 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm |
Conductivity accuracy | ± 0.5 % F.S. |
Conductivity calibration points | 1 - 5 points |
Conductivity calibration solutions | 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm |
TDS range | 0-100 ppt. (max. 200 ppt., depending on factor setting) |
TDS accuracy | ± 1 % F.S. |
TDS factor | 0.1 - 1.0 (default 0.5) |
pH measurement range | (-2.000) to 20.000 pH |
pH accuracy | ± 0.002 pH |
pH calibration points | 1 - 5 points |
pH calibration solutions | USA, NIST, DIN or user defined |
ORP measurement range | -1999.9 to 1999.9 mV |
ORP accuracy | ±0.2 mV |
ORP calibration points | 1 point |
ORP calibration solutions | mV & relative mV |
DO concentration range | 0.00 to 20.00 mg/L |
DO accuracy | ± 0.2 mg/L |
Calibration points | 1 - 2 points |
Pressure correction | 60.0 to 112.5 kPa, 450 - 850 mmHg |