+44 2080 043 608
info@labtron.co
Home
Thermal Cycler
Lab Equipment
Analytical Instruments
Catalogs
About Us
Contact Us
Request A Quote
Company Info
Terms of Use
Policies
Site map
Home
Analytical Instruments
HPLC
Amino Acid Analyzer
Autoclaves
Baths and Circulators
Cabinets
Centrifuge
Freezers
Freeze Dryers
Fume Hood
Muffle Furnace
Tube Furnace
Ice Makers
Incubator
Kjeldahl Systems
Laboratory Shakers and Mixers
Oven
Peristaltic Pump
Refrigerators
Spectrophotometer
Test Chamber
Thermal Cycler
Ultrasonic Cleaner
Vacuum Pump
CO2 Incubator
Thermo-Shakers
Water Purification System
Viscometer
Oven Incubator
Flame Photometer
Microplate Reader & Washer
Petroleum Testing
Solar Powered Products
Chillers
Chromatography
HPLC
Particle Size Analyzer
Gel Documentation
TOC Analyzer
Rotary Evaporator
Polarimeter
Lab Refrigerator-Freezer Combination
Spectrometer
Microscope
Colorimeters
Testing Instruments
Colony Counter
IR Carbon Sulphur Analyzer
Sample Concentrator
Safety Containment Cabinets
Water Testing
Magnetic Stirrers and Hotplates
Microtome
Nucleic Acid Purification System
Moisture Analyzer
Oil And Grease Analyzer
UV Pass Box
Pharmaceutical Testing
V-shell Blender
Differential Thermal Analyzers
Balances
Blood Collection Monitor
Particle Counter
Density Meter
Biochemistry Analyzer
Automatic Glassware Washer
Ultrasonic Homogenizer
Environmental Monitoring Equipments
Refractometer
Water Distillers
Stomacher
Airborne Particle Counters
Hybridization Oven
Platelet Agitator and Incubator
Jar Testers
Electrophoresis System
Milk Analyzers
Potentiometric Titrator
Flammability Tester
Pathology Workstation
BLOOD THAW MACHINE
Opacity Meter
Plasma Extractor
Elemental Analyzer
Plate Sealer
Dosimeter
Stroboscope
Latex Stability Tester
Drug Detector
Wind Meter (Anemometer)
Slide Dryer
Paraffin Trimmer
Vacuum Spin Coater
Ball Mill Machine
Osmometer
ESR Analyzer
Differential Scanning Calorimeters
Water Purifier
Dehumidifier
Vacuum Pycnometer
Gene Electroporator
Laminar Flow Canopy
Fume Extractor
Heating Mantle
Gel Strength Test System
Melting Point Apparatus
Vacuum Filtration Unit
Bottle Top Dispenser
Tachometer
Hydrogen Peroxide Generator
Microwave Digestion System
Sound Level Analysis
X-Ray Machine
Fiber Analysis
Fluorometer
Hybridization System
Semi-automatic Bio-chemistry Analyzer
Soxhlet Apparatus
Color Assessment Cabinet
Leather Softness Tester
Washer Disinfector
Vacuum Packing machine
Glassware Drying Cabinet
Metal Detector
Alloy Analyzer
Blood Bag Tube Sealer
Handheld Homogenizer
Fluorescence Analyzer
Air Permeability Tester
Media Dispensing System
Laser Theodolite
Scintillation Counter
Dispersion Machine
UV Air Sterilizer
HPLC
Standard HPLC
Analytical HPLC
HPLC system LHLC-A10
High pressure pump:
Single pump
Flow rate range:
0.001 - 9.999 mL / min (0.001 mL / min increment)
Pressure range:
≤ 0.5 MPa (0 - 42 MPa)
Flow rate precision:
RSD < 0.06 %
Add to compare
Catalog
HPLC system LHLC-A11
High pressure pump:
Two sets of pump
Flow rate range:
0.001 - 9.999 mL / min (0.001 mL / min increments)
Pressure range:
≤ 0.5 MPa (0 - 42 MPa)
Flow rate precision:
RSD < 0.06 %
Add to compare
Catalog
HPLC system LHLC-B10
High pressure pump:
High pressure gradient pump
Peak operating pressure:
45 MPa, Stainless steel pump
Pressure:
± 0.02 MPa
Flow rate range:
0.001 - 9.999 mL / min
Add to compare
Catalog
HPLC system LHLC-B11
High pressure pump:
High pressure constant-current infusion pump
Infusion Way:
Micro volume series dual-piston
Infusion pressure:
0 - 9999 Psi
Flow rate:
≤ 0.5 %
Add to compare
Catalog
Analytical HPLC System LAHS-A10
Pump specification:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Type</strong></td><td>Quaternary Low Pressure Pump</td></tr><tr><td><strong>Flow Rate Range</strong></td><td>0.001 to 10.000 ml/min, in 0.001ml increments</td></tr><tr><td><strong>Flow Accuracy</strong></td><td>≤ ± 0.2% (1.00 ml/min, H<sub>2 </sub>O, R.T., 8.5 MPa)</td></tr><tr><td><strong>Flow Precision</strong></td><td>RSD ≤ 0.06% (1.00 ml/min, H<sub>2 </sub>O, R.T., 8.5MPa)</td></tr><tr><td><strong>Maximum Pressure</strong></td><td>63 MPa</td></tr><tr><td><strong>Pressure accuracy</strong></td><td>≤ ± 3.0 %</td></tr><tr><td><strong>Pressure pulsation</strong></td><td>≤ 0.1 MPa</td></tr><tr><td><strong>Composition rang</strong></td><td>0 to 100 %</td></tr><tr><td><strong>Composition precision</strong></td><td>≤ 0.3 % RSD</td></tr></table>
UV/VIS Detector:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Wavelength Range</strong></td><td>190 to 800 nm</td></tr><tr><td><strong>Wavelength Repeatability</strong></td><td>≤ 0.1 nm</td></tr><tr><td><strong>Wavelength Accuracy</strong></td><td>≤ ± 1.0 nm</td></tr><tr><td><strong>Band Width</strong></td><td>6 nm</td></tr><tr><td><strong>Response Time</strong></td><td>0.0 s to 5 s</td></tr><tr><td><strong>Baseline Noise</strong></td><td>≤ ± 0.25 × 10<sup>-5 </sup> AU(empty cell, 254 nm, 1.0s)</td></tr><tr><td><strong>Drift</strong></td><td>≤ 0.5 × 10<sup>-4 </sup> AU/h (empty cell, 254 nm, 60 min)</td></tr><tr><td><strong>Path length</strong></td><td>10 mm(analytical cell)</td></tr><tr><td><strong>Light Source</strong></td><td>Deuterium Lamp and Tungsten Lamp</td></tr></table>
Data-processing Workstation:
System contain the tables for regular samples<br/> Equipped with Internal and external standard calculation process<br/> Automatic display, print, export of data and starting of another program on completion on measurement<br/> Observe with the condition of 21 CFR part 11 directive of the FDA
System Kits:
1 Set<br/> Combined A/D converters<br/> Combined vacuum degasser and 4 channel
Add to compare
Catalog
Analytical HPLC System LAHS-B10
High Pressure Constant Flow Pump:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Double plunger reciprocating pump</strong></td><td>1 set</td></tr><tr><td><strong>Flow range</strong></td><td>0.001 to 10.00 mL/min</td></tr><tr><td><strong>Setting step size</strong></td><td>0.001 mL/min</td></tr><tr><td><strong>Flow accuracy</strong></td><td>≤ ± 0.3 %</td></tr><tr><td><strong>Flow stability</strong></td><td>RSD ≤ 00.1 %</td></tr><tr><td><strong>Maximum pressure</strong></td><td>42 MPa</td></tr><tr><td><strong>Display pressure error</strong></td><td>≤ 1.0 %</td></tr><tr><td><strong>Pressure fluctuation</strong></td><td>≤ 1.0 %</td></tr><tr><td><strong>Power consumption</strong></td><td>80 W</td></tr></table>
UV/Visible Detector:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Wavelength range</strong></td><td>190 to 700 nm</td></tr><tr><td><strong>Wavelength repeatability</strong></td><td>± 0.1 nm</td></tr><tr><td><strong>Band width</strong></td><td>8 nm</td></tr><tr><td><strong>Response time</strong></td><td>0 to 4.9 seconds</td></tr><tr><td><strong>Linearity range</strong></td><td>1.8 AU (5 %)</td></tr><tr><td><strong>Baseline Noise</strong></td><td>≤ ± 1 × 10<sup>-5</sup>AU</td></tr><tr><td><strong>Baseline drift</strong></td><td>≤ 2.0 × 10<sup>-4</sup>AU/h</td></tr><tr><td><strong>Minimum detectable concentration</strong></td><td>4.0 × 10<sup>-9</sup> g/mL</td></tr><tr><td><strong>Detector cell</strong></td><td>Optical path: 10 mm<hr> Volume: 10 µL</td></tr><tr><td><strong>Light source</strong></td><td>Deuterium lamp</td></tr><tr><td><strong>Power consumption</strong></td><td>100 W</td></tr><tr><td><strong>Voltage</strong></td><td>AC 110 V/ 220 V ± 10 %, 50/60 Hz</td></tr><tr><td><strong>Packing Dimensions (W × D × H)</strong></td><td>600 × 440 × 380 mm<hr> 2 × (600 × 410 × 300 mm</td></tr><tr><td><strong>Gross weight</strong></td><td>54 kg</td></tr></table>
Add to compare
Catalog
Analytical HPLC System LAHS-B11
High Pressure Constant Flow Pump:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Double plunger reciprocating pump</strong></td><td>2 sets</td></tr><tr><td><strong>Flow range</strong></td><td>0.001 to 10.00 mL/min</td></tr><tr><td><strong>Setting step size</strong></td><td>0.001 mL/min</td></tr><tr><td><strong>Flow accuracy</strong></td><td>≤ ± 0.3 %</td></tr><tr><td><strong>Flow stability</strong></td><td>RSD ≤ 00.1 %</td></tr><tr><td><strong>Maximum pressure</strong></td><td>42 MPa</td></tr><tr><td><strong>Display pressure error</strong></td><td>≤ 1.0 %</td></tr><tr><td><strong>Pressure fluctuation</strong></td><td>≤ 1.0 %</td></tr><tr><td><strong>Power consumption</strong></td><td>80 W</td></tr></table>
UV/Visible Detector:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Wavelength range</strong></td><td>190 to 700 nm</td></tr><tr><td><strong>Wavelength repeatability</strong></td><td>± 0.1 nm</td></tr><tr><td><strong>Band width</strong></td><td>8 nm</td></tr><tr><td><strong>Response time</strong></td><td>0 to 4.9 seconds</td></tr><tr><td><strong>Linearity range</strong></td><td>1.8 AU (5 %)</td></tr><tr><td><strong>Baseline Noise</strong></td><td>≤ ± 1 × 10<sup>-5</sup>AU</td></tr><tr><td><strong>Baseline drift</strong></td><td>≤ 2.0 × 10<sup>-4</sup>AU/h</td></tr><tr><td><strong>Minimum detectable concentration</strong></td><td>4.0 × 10<sup>-9</sup> g/mL</td></tr><tr><td><strong>Detector cell</strong></td><td>Optical path: 10 mm<hr> Volume: 10 µL</td></tr><tr><td><strong>Light source</strong></td><td>Deuterium lamp</td></tr><tr><td><strong>Power consumption</strong></td><td>100 W</td></tr><tr><td><strong>Voltage</strong></td><td>AC 110 V/ 220 V ± 10 %, 50/60 Hz</td></tr><tr><td><strong>Packing Dimensions (W × D × H)</strong></td><td>600 × 440 × 380 mm<hr> 3 × (600 × 410 × 300 mm</td></tr><tr><td><strong>Gross weight</strong></td><td>75 kg</td></tr></table>
Add to compare
Catalog
Analytical HPLC-A7832
Detector Specifications:
<table cellspacing=0 border=1> <tr> <td style=min-width:50px>Model No</td> <td style=min-width:50px>HPD-A20</td> <td style=min-width:50px> HPD-A21</td> </tr> <tr> <td style=min-width:50px>Wavelength range </td> <td style=min-width:50px>Single wavelength ( 190 to 800 nm )</td> <td style=min-width:50px>Dual wavelength ( 190 to 800 nm )</td> </tr> <tr> <td style=min-width:50px>Wavelength accuracy</td> <td style=min-width:50px>± 0.5 nm</td> <td style=min-width:50px>± 2 nm</td> </tr> <tr> <td style=min-width:50px>Wavelength repeatability</td> <td style=min-width:50px>0.15 nm</td> <td style=min-width:50px>0.3 nm</td> </tr> <tr> <td style=min-width:50px>Band width</td> <td style=min-width:50px>8 nm</td> <td style=min-width:50px>8 nm</td> </tr> <tr> <td style=min-width:50px>Optical path</td> <td style=min-width:50px>10 nm</td> <td style=min-width:50px>10 nm</td> </tr> <tr> <td style=min-width:50px>Deuterium lamp</td> <td style=min-width:50px>190 to 400 nm</td> <td style=min-width:50px>190 to 400 nm</td> </tr> <tr> <td style=min-width:50px>Tungsten lamp</td> <td style=min-width:50px>400 to 800 nm</td> <td style=min-width:50px>400 to 800 nm</td> </tr> <tr> <td style=min-width:50px>Baseline noise ( Static ) Au</td> <td style=min-width:50px>≤ ± 0.35 × 10-5</td> <td style=min-width:50px>≤ ± 0.5 × 10-5</td> </tr> <tr> <td style=min-width:50px>Baseline drift ( Static ) Au / h</td> <td style=min-width:50px>≤ 1 × 10-4</td> <td style=min-width:50px>≤ 1.5 × 10-4</td> </tr> <tr> <td style=min-width:50px>Minimum detection limit</td> <td style=min-width:50px>≤ 4 × 10-8</td> <td style=min-width:50px>≤ 4 × 10-8</td> </tr> <tr> <td style=min-width:50px>Power</td> <td style=min-width:50px>100 W</td> <td style=min-width:50px>100 W</td> </tr> <tr> <td style=min-width:50px>Power supply</td> <td style=min-width:50px>90 V / 50 to 60 Hz</td> <td style=min-width:50px>90 V / 50 to 60 Hz</td> </tr> <tr> <td style=min-width:50px>Dimension</td> <td style=min-width:50px>460 × 315 × 180 mm</td> <td style=min-width:50px>460 × 315 × 180 mm</td> </tr> <tr> <td style=min-width:50px>Weight</td> <td style=min-width:50px>9.5 kg</td> <td style=min-width:50px>9.5 kg</td> </tr> </table>
Pump Specifications:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Flow rate range</strong></td><td>0.0001 to 10 ml / min</td></tr><tr><td><strong>Maximum pressure</strong></td><td>50 MPa , 0 to 2 ml / min</td></tr><tr><td><strong>Column size</strong></td><td>4.6 × 250 mm</td></tr><tr><td><strong>Sample size</strong></td><td>5 µm</td></tr><tr><td><strong>Pressure pulsation</strong></td><td>≤ 1 % at 10 MPa</td></tr><tr><td><strong>Flow rate accuracy</strong></td><td>± 0.15 % at 1 ml / min</td></tr><tr><td><strong>Flow rate repeatability %</strong></td><td>≤ 0.1</td></tr><tr><td><strong>Gradient accuracy %</strong></td><td>± 1.5</td></tr><tr><td><strong>Gradient repeatability %</strong></td><td>≤ 0.2</td></tr><tr><td><strong>Dimension</strong></td><td>460 × 310 × 180 mm</td></tr><tr><td><strong>Power supply</strong></td><td>90 V</td></tr><tr><td><strong>Weight</strong></td><td>11.6 kg</td></tr></table>
Add to compare
Catalog
Analytical HPLC-A7835
Pump Specifications:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Model No</strong></td><td>HPP-B1</td></tr><tr><td><strong>Flow rate range</strong></td><td>0.0001 to 10 ml / min</td></tr><tr><td><strong>Maximum pressure</strong></td><td>42 MPa , 0 to 5 ml / min</td></tr><tr><td><strong>Column size</strong></td><td>4.6 × 250 mm</td></tr><tr><td><strong>Sample size</strong></td><td>5 μm</td></tr><tr><td><strong>Pressure pulsation</strong></td><td>≤ 1.5 % at 10 MPa</td></tr><tr><td><strong>Flow rate accuracy</strong></td><td>± 0.2 % at 1 ml / min</td></tr><tr><td><strong>Flow rate repeatability %</strong></td><td>≤ 0.15</td></tr><tr><td><strong>Gradient accuracy %</strong></td><td>± 2</td></tr><tr><td><strong>Gradient repeatability %</strong></td><td>≤ 0.2</td></tr><tr><td><strong>Dimension</strong></td><td>450 × 260 × 190 mm</td></tr><tr><td><strong>Power supply</strong></td><td>90 V to 240 V</td></tr><tr><td><strong>Weight</strong></td><td>11.2 kg</td></tr></table>
Detector Specifications:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Model No</strong></td><td>HPD-B2</td></tr><tr><td><strong>Wavelength range</strong></td><td>190 to 800 nm</td></tr><tr><td><strong>Wavelength accuracy</strong></td><td>± 0.75 nm</td></tr><tr><td><strong>Wavelength repeatability</strong></td><td>0.2 nm</td></tr><tr><td><strong>Band width</strong></td><td>8 nm</td></tr><tr><td><strong>Optical path</strong></td><td>10 nm</td></tr><tr><td><strong>Deuterium lamp</strong></td><td>190 to 400 nm</td></tr><tr><td><strong>Tungsten lamp</strong></td><td>400 to 800 nm</td></tr><tr><td><strong>Baseline noise ( Static ) Au</strong></td><td>≤ ± 0.5 × 10 <sup>-5</sup></td></tr><tr><td><strong>Baseline drift ( Static ) Au / h</strong></td><td>≤ 1.5 x 10 <sup>-4</sup></td></tr><tr><td><strong>Minimum detection limit</strong></td><td>≤ 4 x 10 <sup>-8</sup></td></tr><tr><td><strong>Power</strong></td><td>100 W</td></tr><tr><td><strong>Power supply</strong></td><td>90 V / 50 to 60 Hz</td></tr><tr><td><strong>Dimension</strong></td><td>460 × 260 × 190 mm</td></tr><tr><td><strong>Weight</strong></td><td>9.2 kg</td></tr></table>
Add to compare
Catalog
Analytical HPLC-A7840
Pump Specifications:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Solvent delivery</strong></td><td>Double plunger series mode, floating plunger design, single stroke volume 30 µl</td></tr><tr><td><strong>Pump Head</strong></td><td>10 ml stainless steel pump head</td></tr><tr><td><strong>Flow rate range</strong></td><td>0.001 to 9.999 ml / min</td></tr><tr><td><strong>Flow rate increment</strong></td><td>0.001 ml/min</td></tr><tr><td><strong>Maximum pressure</strong></td><td>42 MPa</td></tr><tr><td><strong>Column size</strong></td><td>4.6 × 250 mm 5 µm</td></tr><tr><td><strong>Pipeline Size</strong></td><td>1/16 inch</td></tr><tr><td><strong>Flow rate accuracy</strong></td><td>± 0.5 %</td></tr><tr><td><strong>Flow rate precision</strong></td><td>RSD ≤ 0.1%</td></tr><tr><td><strong>Gradient accuracy %</strong></td><td>± 0.5 %</td></tr><tr><td><strong>Gradient repeatability %</strong></td><td>RSD ≤ 0.15%</td></tr><tr><td><strong>GLP</strong></td><td>Automatic recording of pump sealing ring working time</td></tr><tr><td><strong>Display</strong></td><td>LCD backlight display</td></tr><tr><td><strong>Power</strong></td><td>80 W</td></tr><tr><td><strong>Power supply</strong></td><td>220 V ± 10%, 50 Hz</td></tr><tr><td><strong>Dimension</strong></td><td>398 × 149 × 267 mm</td></tr></table>
Detector Specifications:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Wavelength range</strong></td><td>190 to 700 nm</td></tr><tr><td><strong>Wavelength accuracy</strong></td><td>± 1 nm</td></tr><tr><td><strong>Wavelength repeatability</strong></td><td>0.2 nm</td></tr><tr><td><strong>Deuterium lamp</strong></td><td>190 to 400 nm</td></tr><tr><td><strong>Tungsten lamp</strong></td><td>400 to 700 nm</td></tr><tr><td><strong>Baseline noise ( Static ) Au</strong></td><td>1 × 10<sup>-5</sup> AU/h at 254 nm with methanol/water= 80/20</td></tr><tr><td><strong>Baseline drift ( Static ) Au / h</strong></td><td>1.5 × 10<sup>-4</sup> AU/h at 254 nm with methanol/ water= 80/20</td></tr><tr><td><strong>Time constants</strong></td><td>16 grades adjustable</td></tr><tr><td><strong>Display</strong></td><td>LCD backlight display</td></tr><tr><td><strong>GLP</strong></td><td>Total number of lights, lamp replacement time and product serial number</td></tr><tr><td><strong>Power</strong></td><td>75 W</td></tr><tr><td><strong>Power supply</strong></td><td>220 V ± 10%, 50 Hz</td></tr><tr><td><strong>Dimension (L × W × H)</strong></td><td>398 × 149 × 267 mm</td></tr></table>
Add to compare
Catalog
COMPARE
×
Request Quote Form
Name
Email
Company
Product
Details:
SUBMIT