+44 2080 043 608
info@labtron.co
Home
Thermal Cycler
Lab Equipment
Analytical Instruments
Catalogs
About Us
Contact Us
Request A Quote
Company Info
Terms of Use
Policies
Site map
Home
Analytical Instruments
Chromatography
Amino Acid Analyzer
Autoclaves
Baths and Circulators
Cabinets
Centrifuge
Freezers
Freeze Dryers
Fume Hood
Muffle Furnace
Tube Furnace
Ice Makers
Incubator
Kjeldahl Systems
Laboratory Shakers and Mixers
Oven
Peristaltic Pump
Refrigerators
Spectrophotometer
Test Chamber
Thermal Cycler
Ultrasonic Cleaner
Vacuum Pump
CO2 Incubator
Thermo-Shakers
Water Purification System
Viscometer
Oven Incubator
Flame Photometer
Microplate Reader & Washer
Petroleum Testing
Solar Powered Products
Chillers
Chromatography
HPLC
Particle Size Analyzer
Gel Documentation
TOC Analyzer
Rotary Evaporator
Polarimeter
Lab Refrigerator-Freezer Combination
Spectrometer
Microscope
Colorimeters
Testing Instruments
Colony Counter
IR Carbon Sulphur Analyzer
Sample Concentrator
Safety Containment Cabinets
Water Testing
Magnetic Stirrers and Hotplates
Microtome
Nucleic Acid Purification System
Moisture Analyzer
Oil And Grease Analyzer
UV Pass Box
Pharmaceutical Testing
V-shell Blender
Differential Thermal Analyzers
Balances
Blood Collection Monitor
Particle Counter
Density Meter
Biochemistry Analyzer
Automatic Glassware Washer
Ultrasonic Homogenizer
Environmental Monitoring Equipments
Refractometer
Water Distillers
Stomacher
Airborne Particle Counters
Hybridization Oven
Platelet Agitator and Incubator
Jar Testers
Electrophoresis System
Milk Analyzers
Potentiometric Titrator
Flammability Tester
Pathology Workstation
BLOOD THAW MACHINE
Opacity Meter
Plasma Extractor
Elemental Analyzer
Plate Sealer
Dosimeter
Stroboscope
Latex Stability Tester
Drug Detector
Wind Meter (Anemometer)
Slide Dryer
Paraffin Trimmer
Vacuum Spin Coater
Ball Mill Machine
Osmometer
ESR Analyzer
Differential Scanning Calorimeters
Water Purifier
Dehumidifier
Vacuum Pycnometer
Gene Electroporator
Laminar Flow Canopy
Fume Extractor
Heating Mantle
Gel Strength Test System
Melting Point Apparatus
Vacuum Filtration Unit
Bottle Top Dispenser
Tachometer
Hydrogen Peroxide Generator
Microwave Digestion System
Sound Level Analysis
X-Ray Machine
Fiber Analysis
Fluorometer
Hybridization System
Semi-automatic Bio-chemistry Analyzer
Soxhlet Apparatus
Color Assessment Cabinet
Leather Softness Tester
Washer Disinfector
Vacuum Packing machine
Glassware Drying Cabinet
Metal Detector
Alloy Analyzer
Blood Bag Tube Sealer
Handheld Homogenizer
Fluorescence Analyzer
Air Permeability Tester
Media Dispensing System
Laser Theodolite
Scintillation Counter
Dispersion Machine
UV Air Sterilizer
Chromatography
Gas Chromatography
Ion Chromatography
GC-MS
Portable Ion Chromatograph
Gas Chromatography LGC-B11
Oven:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Maximum capacity</strong></td><td>22 L</td></tr><tr><td><strong>Temperature range</strong></td><td>RT + 5 ℃ to 400 ℃</td></tr><tr><td><strong>Temperature accuracy</strong></td><td>± 0.1 ℃</td></tr><tr><td><strong>Temperature program</strong></td><td>9-phase/ 10 platform</td></tr><tr><td><strong>Program total time</strong></td><td>9999.9 min</td></tr><tr><td><strong>Maximum temperature heating rate</strong></td><td>0.1 to 60 ℃/ min</td></tr><tr><td><strong>Maximum cooling rate</strong></td><td>˂ 10 mins (250 to 50 ℃)</td></tr></table>
Sample injector:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Temperature range</strong></td><td>RT+ 7 ℃ to 420 ℃</td></tr><tr><td><strong>Temperature control</strong></td><td>Automatic</td></tr><tr><td><strong>Injector type</strong></td><td>Column or split</td></tr><tr><td><strong>Maximum sample inlet</strong></td><td>3 pcs</td></tr><tr><td><strong>Carrier gas flow type</strong></td><td>Constant pressure</td></tr><tr><td><strong>Pre column pressure range</strong></td><td>0 to 400 kPa</td></tr><tr><td><strong>Pre column pressure accuracy</strong></td><td>0.1 kPa</td></tr><tr><td><strong>Mobile phase flow range</strong></td><td>H2: 0 to 200 ml/min, N2: 0 to 150 ml/min</td></tr></table>
Detector:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Temperature range</strong></td><td>RT + 7 ℃ to 420 ℃</td></tr><tr><td><strong>Maximum installation</strong></td><td>Dual detector</td></tr><tr><td><strong>Flame ignition mode</strong></td><td>Automatic</td></tr><tr><td><strong>Flame Ionization Detector (FID)</strong></td><td>Logarithmic amplifier <br/> High voltage switch control <br/> Baseline signal display <br/> Ignition coil control <br/> Detection limit: ≤3 ×10 to 12 g/s (Sample: n-hexadecane) <br/> Baseline noise: ≤ 5 × 10 <sup> - 14 </sup> A <br/> Baseline draft: ≤ 6 × 10 <sup> -13 </sup> A <br/> Dynamic range: 10 <sup> 7 </sup> <br/> RSD: ≤ 3 %</td></tr></table>
Power supply:
AC 220 V ± 22 V, 50 Hz ± 0.5 Hz, 3000 W
Add to compare
Catalog
Ion chromatograph system LICS-A20
Ion Chromatographic Pump:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Type</strong></td><td>High pressure and low pulse double plunger tandem advection pump</td></tr><tr><td><strong>Maximum pressure</strong></td><td>35 MPa (PEEK)</td></tr><tr><td><strong>Pressure display accuracy</strong></td><td>≤ 0.1 MPa</td></tr><tr><td><strong>Flow stability</strong></td><td>(0.2 to 0.5) ml/ min ≤ 3 %<br/> (0.5 to 1.0) ml/ min ≤ 2 %<br/> > 1.0 ml/ min 2 %<br/></td></tr><tr><td><strong>Flow range</strong></td><td>0.001 to 9.999 ml/ min</td></tr><tr><td><strong>Pressure pulse</strong></td><td>≤ 0.5%</td></tr></table>
Conductivity detector:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Type</strong></td><td>Temperature Control and Bipolar Conductivity Detector</td></tr><tr><td><strong>Detection mode</strong></td><td>Bipolar conductivity detection</td></tr><tr><td><strong>Cell volume</strong></td><td>≤ 0.8 µL</td></tr><tr><td><strong>Detection range</strong></td><td>0 to 35000 µS/ cm</td></tr><tr><td><strong>Detection resolution</strong></td><td>≤ 0.0020 nS/ cm</td></tr><tr><td><strong>Output voltage</strong></td><td>- 6000 to +6000 mV (adjustable)</td></tr><tr><td><strong>Baseline noise</strong></td><td>≤ 0.05 % F.S.</td></tr><tr><td><strong>Baseline drift</strong></td><td>≤ 3 % FS/ 30 min</td></tr><tr><td><strong>Operating temperature range</strong></td><td>Room temperature +5 to 60°C (41 to 140°F)</td></tr><tr><td><strong>Controlling temperature accuracy</strong></td><td>± 0.01°C</td></tr><tr><td><strong>Maximum pressure</strong></td><td>10 MPa</td></tr><tr><td><strong>Linear range</strong></td><td>≥ 103</td></tr><tr><td><strong>Instruments linearity</strong></td><td>≥ 0.999</td></tr><tr><td><strong>Quantitative repeatability</strong></td><td>≤ 1.0 %</td></tr><tr><td><strong>Qualitative repeatability</strong></td><td>≤ 1.0 %</td></tr><tr><td><strong>Minimum detectable concentration</strong></td><td>Cl ≤ 0.0005 ug/ ml<br/> BrO3 ≤ 0.001 ug/ ml<br/> Li+ ≤ 0.001 ug/ ml</td></tr></table>
Flow system:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Plastic flow path</strong></td><td>Made of PEEK materials</td></tr><tr><td><strong>Six way Valve</strong></td><td>PEEK material, 5000 psi pressure, independent automatic collection and flow function</td></tr></table>
Degassing Device:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Inner volume</strong></td><td>300 µl</td></tr><tr><td><strong>Degassing volume</strong></td><td>7.5 ml</td></tr><tr><td><strong>Maximum flow rate</strong></td><td>10 ml/ min</td></tr><tr><td><strong>Degassing efficiency</strong></td><td>Degassing 90 % at 1ml/ min</td></tr><tr><td><strong>Organic tolerance</strong></td><td>1</td></tr></table>
Add to compare
Catalog
Ion chromatograph system LICS-A21
Ion Chromatographic Pump:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Type</strong></td><td>High pressure and low pulse double plunger tandem advection pump</td></tr><tr><td><strong>Maximum pressure</strong></td><td>35 MPa (PEEK)</td></tr><tr><td><strong>Pressure display accuracy</strong></td><td>≤ 0.1 MPa</td></tr><tr><td><strong>Flow stability</strong></td><td>(0.2 to 0.5) ml/ min ≤ 3 %<br/> (0.5 to 1.0) ml/ min ≤ 2 %<br/> > 1.0 ml/ min 2 %</td></tr><tr><td><strong>Flow range</strong></td><td>0.001 to 9.999 ml/ min</td></tr><tr><td><strong>Pressure pulse</strong></td><td>≤ 0.5%</td></tr></table>
Conductivity detector:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Type</strong></td><td>Temperature Control and Bipolar Conductivity Detector</td></tr><tr><td><strong>Detection mode</strong></td><td>Bipolar conductivity detection</td></tr><tr><td><strong>Cell volume</strong></td><td>≤ 0.8 µL</td></tr><tr><td><strong>Detection range</strong></td><td>0 to 45000 µS/ cm</td></tr><tr><td><strong>Detection resolution</strong></td><td>≤ 0.0020 nS/ cm</td></tr><tr><td><strong>Output voltage</strong></td><td>- 6000 to +6000 mV (adjustable)</td></tr><tr><td><strong>Baseline noise</strong></td><td>≤ 0.05 % F.S.</td></tr><tr><td><strong>Baseline drift</strong></td><td>≤ 3 % FS/ 30 min</td></tr><tr><td><strong>Operating temperature range</strong></td><td>Room temperature +5 to 60°C (41 to 140°F)</td></tr><tr><td><strong>Controlling temperature accuracy</strong></td><td>± 0.01°C</td></tr><tr><td><strong>Maximum pressure</strong></td><td>10 MPa</td></tr><tr><td><strong>Linear range</strong></td><td>≥ 103</td></tr><tr><td><strong>Instruments linearity</strong></td><td>≥ 0.999</td></tr><tr><td><strong>Quantitative repeatability</strong></td><td>≤ 1.0 %</td></tr><tr><td><strong>Qualitative repeatability</strong></td><td>≤ 1.0 %</td></tr><tr><td><strong>Minimum detectable concentration</strong></td><td>Cl ≤ 0.0005 ug/ ml<br/> BrO3 ≤ 0.001 ug/ ml<br/> Li+ ≤ 0.001 ug/ ml</td></tr></table>
Flow system:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Plastic flow path</strong></td><td>Made of PEEK materials</td></tr><tr><td><strong>Six way Valve</strong></td><td>PEEK material, 5000 psi pressure, independent automatic collection and flow function</td></tr></table>
Power supply:
150 W
Add to compare
Catalog
Ion chromatograph system LICS-A22
Ion Chromatographic pump:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Type</strong></td><td>High pressure and low pulse double plunger tandem advection pump</td></tr><tr><td><strong>Maximum pressure</strong></td><td>35 MPa (PEEK)</td></tr><tr><td><strong>Display pressure accuracy</strong></td><td>≤ 0.1 MPa</td></tr><tr><td><strong>Flow stability</strong></td><td>(0.2 to 0.5) ml/ min ≤ 3 % , (0.5 to 1.0) ml/ min ≤ 2 %, > 1.0 ml/ min ≤ 2 %</td></tr><tr><td><strong>Flow range</strong></td><td>0.001 to 9.999 ml/ min</td></tr><tr><td><strong>Pressure pulse</strong></td><td>≤ 0.5 %</td></tr></table>
Numerical control and electromagnetic injection:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Maximum pressure</strong></td><td>35 MPa</td></tr><tr><td><strong>Contact material of the rotor</strong></td><td>PEEK</td></tr><tr><td><strong>Control mode</strong></td><td>By Stepper motor</td></tr><tr><td><strong>Power supply</strong></td><td>DC 24 V</td></tr></table>
Column heater:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Operating temperature range</strong></td><td>Room temperature 20 to 60°C ( 68 to 140°F)</td></tr><tr><td><strong>Controlling temperature accuracy</strong></td><td>± 0.01°C</td></tr><tr><td><strong>Allowable deviation of column heater temperature</strong></td><td>± 2°C</td></tr><tr><td><strong>Temperature stability</strong></td><td>≤ 1°C/ h</td></tr></table>
Flow system:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Plastic flow path</strong></td><td>Made up of PEEK material</td></tr><tr><td><strong>Six way valve</strong></td><td>PEEK material pressure 5000 psi, independent automatic collection and flow function</td></tr></table>
Add to compare
Catalog
Gas chromatography mass spectrometry GC-MS-879
Gas Chromatography Specifications:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Model No</strong></td><td>GC-87</td></tr><tr><td><strong>Flow rate</strong></td><td>1 ~ 1.5 ml / min</td></tr><tr><td><strong>Maximum flow rate</strong></td><td>10 ml / min</td></tr><tr><td><strong>Inlet temperature</strong></td><td>450 °C</td></tr><tr><td><strong>Pressure range</strong></td><td>0 ~ 100 psi</td></tr><tr><td><strong>Heating rate</strong></td><td>Upto 120 °C / min</td></tr><tr><td><strong>Room temperature</strong></td><td>4 °C ~ 450 °C</td></tr><tr><td><strong>Pressure control mode</strong></td><td>Electronic pressure control ( Supports CV and CC )</td></tr><tr><td><strong>Split mode</strong></td><td>Split / split less</td></tr><tr><td><strong>Split ratio</strong></td><td>1000 : 1</td></tr><tr><td><strong>Temperature programming</strong></td><td>7 stages / 8 platforms</td></tr><tr><td><strong>Auto sampler</strong></td><td>Optional</td></tr></table>
Mass Spectrometry Specifications:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Model No</strong></td><td>MS-89</td></tr><tr><td><strong>Mass range</strong></td><td>1.5 ~ 1000 amu</td></tr><tr><td><strong>Ion – source temperature</strong></td><td>100 °C ~ 350 °C</td></tr><tr><td><strong>GC-MS interface temperature</strong></td><td>450 °C</td></tr><tr><td><strong>Scan rate</strong></td><td>Upto 10000 amu/s</td></tr><tr><td><strong>Stability</strong></td><td>± 0.10 amu / 48 hrs.</td></tr><tr><td><strong>Filament emission current</strong></td><td>0 ~ 350 µA</td></tr><tr><td><strong>EI source ionization energy</strong></td><td>5 eV ~ 250 eV</td></tr><tr><td><strong>Resolution</strong></td><td>Unit resolution</td></tr><tr><td><strong>Detector</strong></td><td>High energy dynode electron multiplier</td></tr><tr><td><strong>Sensitivity</strong></td><td>Full scan ( S / N is ≥ 30 : 1 )</td></tr><tr><td><strong>Vacuum</strong></td><td>Turbo molecular pump ( 67 L/s )</td></tr></table>
Add to compare
Catalog
Ion Chromatograph LPIC-A10
Chromatographic Pump:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Type</strong></td><td>High-pressure and low –pulse double plunger tandem advection pump</td></tr><tr><td><strong>Maximum Pressure</strong></td><td>35 MPa (PEEK)</td></tr><tr><td><strong>Flow Range</strong></td><td>0.001 to 9.999 mL/min</td></tr><tr><td><strong>Flow accuracy</strong></td><td>± 0.5 %</td></tr><tr><td><strong>Flow Repeatability</strong></td><td>RSD ≤ 0.1%</td></tr><tr><td><strong>Flow stability</strong></td><td>(0.2 to 0.5) mL/min, ≤ 3 %<br/> (0.5 to 1.0) mL/min, ≤ 2 %<br/> >1.0 mL/min, ≤ 2 %</td></tr></table>
Built-in Heat conduction type column heater:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Temperature range</strong></td><td>Room temperature +5°C to 60°C (41 to 140°F)</td></tr><tr><td><strong>Allowable deviation</strong></td><td>± 1°C</td></tr><tr><td><strong>Temperature stability</strong></td><td>≤ 0.5°C/h</td></tr></table>
Electromagnetic injection valve:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Maximum pressure</strong></td><td>35 MPa</td></tr><tr><td><strong>Control mode</strong></td><td>By stepper motor</td></tr><tr><td><strong>Power supply</strong></td><td>24 V (DC)</td></tr></table>
Digital and temperature control detection system:
<table class="table table-striped table-bordered table-responsive"><tr><td><strong>Type</strong></td><td>Temperature control and bipolar conductivity detector</td></tr><tr><td><strong>Detection type</strong></td><td>Bipolar conductivity detection</td></tr><tr><td><strong>Cell volume</strong></td><td>≤ 0.8 µL</td></tr><tr><td><strong>Measurement range</strong></td><td>0 to 45000 µ S/cm (adjustable)</td></tr><tr><td><strong>Detection resolution</strong></td><td>≤ 0.0020 nS/cm</td></tr><tr><td><strong>Output voltage</strong></td><td>-6000 to 6000 mV (adjustable)</td></tr><tr><td><strong>Temperature range</strong></td><td>Room temperature +5°C to 60°C (41 to 140°F)</td></tr><tr><td><strong>Temperature accuracy</strong></td><td>± 0.01°C</td></tr><tr><td><strong>Maximum pressure</strong></td><td>10 MPa</td></tr><tr><td><strong>Baseline drift</strong></td><td>≤ 20 % FS/30 min</td></tr><tr><td><strong>Baseline noise</strong></td><td>≤0.5 % FS</td></tr><tr><td><strong>Instrument linearity</strong></td><td>≥ 0.999</td></tr><tr><td><strong>Quantitative Repeatability</strong></td><td>≤0.5 %</td></tr><tr><td><strong>Qualitative Repeatability</strong></td><td>≤2 %</td></tr><tr><td><strong>Minimum detectable concentration</strong></td><td>Cl-≤0.005 µg/mL<br/> Li+ ≤0.005 µg/mL</td></tr></table>
Add to compare
Catalog
COMPARE
×
Request Quote Form
Name
Email
Company
Product
Details:
SUBMIT