Analytical HPLC : Analytical HPLC System LAHS-A10


Share :



Analytical HPLC System LAHS-A10 features Quaternary Low Pressure Pump with 0.001-10 ml/min pump flow rate. Incorporated UV-Vis detector with a range of 190 to 800 nm that examines sample absorption at different wavelengths and a high pressure pump providing continuous stable flow. This HPLC system offers high speed accuracy, resolving power, detection, quantification, convenience and applicability to new sample types. 



Available Range :

Detector Specifications :
Model No HPD-A20 HPD-A21
Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm )
Wavelength accuracy ± 0.5 nm ± 2 nm
Wavelength repeatability 0.15 nm 0.3 nm
Band width 8 nm 8 nm
Optical path 10 nm 10 nm
Deuterium lamp 190 to 400 nm 190 to 400 nm
Tungsten lamp 400 to 800 nm 400 to 800 nm
Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5
Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4
Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8
Power 100 W 100 W
Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz
Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm
Weight 9.5 kg 9.5 kg
Pump Specifications : Model No : HPP-B1 Detector Specifications : Model No : HPD-B2 Pump specification : Type : Quaternary Low Pressure Pump UV/VIS Detector : Wavelength Range : 190 to 800 nm Data-processing Workstation : System contain the tables for regular samples
Equipped with Internal and external standard calculation process
Automatic display, print, export of data and starting of another program on completion on measurement
Observe with the condition of 21 CFR part 11 directive of the FDA
High Pressure Constant Flow Pump : Double plunger reciprocating pump : 1 set UV/Visible Detector : Wavelength range : 190 to 700 nm High Pressure Constant Flow Pump : Double plunger reciprocating pump : 2 sets UV/Visible Detector : Wavelength range : 190 to 700 nm Pump Specifications : Solvent delivery : Double plunger series mode, floating plunger design, single stroke volume 30 µl Detector Specifications : Wavelength range : 190 to 700 nm
Pump specification
TypeQuaternary Low Pressure Pump
Flow Rate Range0.001 to 10.000 ml/min, in 0.001ml increments
Flow Accuracy≤ ± 0.2% (1.00 ml/min, H2 O, R.T., 8.5 MPa)
Flow PrecisionRSD ≤ 0.06% (1.00 ml/min, H2 O, R.T., 8.5MPa)
Maximum Pressure63 MPa
Pressure accuracy≤ ± 3.0 %
Pressure pulsation≤ 0.1 MPa
Composition rang0 to 100 %
Composition precision≤ 0.3 % RSD
UV/VIS Detector
Wavelength Range190 to 800 nm
Wavelength Repeatability≤ 0.1 nm
Wavelength Accuracy≤ ± 1.0 nm
Band Width6 nm
Response Time0.0 s to 5 s
Baseline Noise≤ ± 0.25 × 10-5 AU(empty cell, 254 nm, 1.0s)
Drift≤ 0.5 × 10-4 AU/h (empty cell, 254 nm, 60 min)
Path length10 mm(analytical cell)
Light SourceDeuterium Lamp and Tungsten Lamp
Data-processing WorkstationSystem contain the tables for regular samples
Equipped with Internal and external standard calculation process
Automatic display, print, export of data and starting of another program on completion on measurement
Observe with the condition of 21 CFR part 11 directive of the FDA
System Kits1 Set
Combined A/D converters
Combined vacuum degasser and 4 channel
Power SupplyAC 110 /220 V ±1 0 %, 50/60 Hz
Dimension710 × 583× 500mm; 770 × 450 × 700 mm
Weight156 kg
  • UV-Vis detector with a range of 190 to 800 nm
  • Consist of Quaternary Low Pressure Pump
  • Advance and intellectual HPLC system
  • Excellent Flow Accuracy and Pressure Accuracy
  • Column oven with greater capacity of 3 column with maximum thickness ID10 × 250 mm
  • Fast and stable UDP communication protocol, can be used for instrument remote control
  • Enhancement of up to 5 mm stroke of plunger rod with good performance and high pressure constant flow pump or parallel pump head
  • Complies with FDA 21 CFR part 11
High Performance Liquid Chromatography system has been widely used in Research and Development, pharmaceutical, food nutrient analysis of amino acids and sugars, detection of food contaminants, environmental pollutant and chemical product purity.
Degasser
Accessories no. Name
1 Column oven
2 Auto sampler
3 Degasser
4 Diode Array Detector
5 Refractive Index Detector
6 Evaporative Light Scattering Detector
7 Fluorescence Detector

Standard HPLC

Labtron Standard HPLC analyze complex mixtures efficiently and provides valuable data for both qualitative and quantitative analysis. They achieve high resolution with fine column packing and optimized flow rates. Their high-pressure pump offers precise mixing, sleek design and easy operation. The UV detector includes dual-beam monochromator, light battery, and deuterium lamp for accuracy. Our Standard HPLC is essential for precise compound analysis in pharmaceuticals, food, environmental studies, biotechnology, and forensics.

Standard HPLC : HPLC system LHLC-A10
  • High pressure pump
  • Single pump
  • Flow rate range
  • 0.001 - 9.999 mL / min (0.001 mL / min increment)
  • Pressure range
  • ≤ 0.5 MPa (0 - 42 MPa)
Standard HPLC : HPLC system LHLC-A11
  • High pressure pump
  • Two sets of pump
  • Flow rate range
  • 0.001 - 9.999 mL / min (0.001 mL / min increments)
  • Pressure range
  • ≤ 0.5 MPa (0 - 42 MPa)
Standard HPLC : HPLC system LHLC-B11
  • High pressure pump
  • High pressure constant-current infusion pump
  • Infusion Way
  • Micro volume series dual-piston
  • Infusion pressure
  • 0 - 9999 Psi
Standard HPLC : HPLC system LHLC-B10
  • High pressure pump
  • High pressure gradient pump
  • Peak operating pressure
  • 45 MPa, Stainless steel pump
  • Pressure
  • ± 0.02 MPa

Analytical HPLC

Labtron Analytical HPLC measures compounds in mixtures using column and detector system. They have deuterium and tungsten lamps that work together for both flexible and accurate detection. Measurement can be performed with three different methods for precise analysis. The system offers control via panel or computer for easy parameter and pump management. Our Analytical HPLC ideal for precise separation, identification, and quantification of compounds in various samples.

Analytical HPLC : Analytical HPLC-A7840
  • Pump Specifications
  • Double plunger series mode, floating plunger design, single stroke volume 30 µl
  • Detector Specifications
  • 190 to 700 nm
Analytical HPLC : Analytical HPLC-A7835
  • Pump Specifications
  • HPP-B1
  • Detector Specifications
  • HPD-B2
Analytical HPLC : Analytical HPLC-A7832
  • Detector Specifications
  • Model No HPD-A20 HPD-A21 Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm ) Wavelength accuracy ± 0.5 nm ± 2 nm Wavelength repeatability 0.15 nm 0.3 nm Band width 8 nm 8 nm Optical path 10 nm 10 nm Deuterium lamp 190 to 400 nm 190 to 400 nm Tungsten lamp 400 to 800 nm 400 to 800 nm Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5 Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4 Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8 Power 100 W 100 W Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm Weight 9.5 kg 9.5 kg
  • Pump Specifications
  • 0.0001 to 10 ml / min
Analytical HPLC : Analytical HPLC System LAHS-B10
  • High Pressure Constant Flow Pump
  • 1 set
  • UV/Visible Detector
  • 190 to 700 nm