Standard HPLC : HPLC system LHLC-A11


Share :



This model of HPLC gradient system is equipped with 2 sets of high-pressure constant-current pump and ultraviolet detector. Its microprocessor reciprocating plunger pump comes with functions such as high working pressure, low pulse rate. This gradient HPLC model meet the needs of conventional analysis to micro flow analysis.



Available Range :

High pressure pump : Single pump High pressure pump : Two sets of pump High pressure pump : High pressure gradient pump High pressure pump : High pressure constant-current infusion pump
High pressure pumpTwo sets of pump
Flow rate range0.001 - 9.999 mL / min (0.001 mL / min increments)
Pressure range≤ 0.5 MPa (0 - 42 MPa)
Flow rate precisionRSD < 0.06 %
Pulsation≤ 0.1 MPa (flow rate 1 ml / min, Pressure 5 - 10 MPa)
Qualitative analysisRSD 6 ≤ 0.1 % (naphthalene methyl alcohol solvent)
Quantitative repeatabilityRSD 6 ≤ 0.3 % (naphthalene methyl alcohol solvent)
Flow rate setting errorSs ≤ 2 % (1 mL / min water, 5 - 10 MPa room temperature)
Air tightness of the pumpPressure 42 MPa, 10 min time, Pressure drop < 0.5 MPa
Mixing accuracy± 1 %
Mixing precision± 0.2 %
Size (W × H × D)450 × 300 × 160 mm
UV Detector
Wavelength range190 - 680 nm
Flow cell8 µL
Spectrum band width8 nm
Baseline noise≤ ± 0.25 × 10-5 AU (empty cell)
Wavelength accuracy± 1 nm
Baseline drift≤ ± 0.4 × 10-4 AU (empty cell)
Wavelength precision< 0.1 nm
Limit of detection3 × 10-9 g / mL (naphthalene methyl alcohol solvent)
Size (W × H × D)450 × 300 × 160 mm
  • More precise optical system for the high precision and small offset
  • Improved light energy through the parallel double cone flow cell
  • Significant reduction in the static noise of the instrument and signal drift
This HPLC system has applications in the field of biochemistry, chemistry, pharmacology for chemical analysis, poison analysis and in protein food detection, medicine testing and polymer, environmental analysis.

Standard HPLC

Labtron Standard HPLC analyze complex mixtures efficiently and provides valuable data for both qualitative and quantitative analysis. They achieve high resolution with fine column packing and optimized flow rates. Their high-pressure pump offers precise mixing, sleek design and easy operation. The UV detector includes dual-beam monochromator, light battery, and deuterium lamp for accuracy. Our Standard HPLC is essential for precise compound analysis in pharmaceuticals, food, environmental studies, biotechnology, and forensics.

Standard HPLC : HPLC system LHLC-A10
  • High pressure pump
  • Single pump
  • Flow rate range
  • 0.001 - 9.999 mL / min (0.001 mL / min increment)
  • Pressure range
  • ≤ 0.5 MPa (0 - 42 MPa)
Standard HPLC : HPLC system LHLC-B11
  • High pressure pump
  • High pressure constant-current infusion pump
  • Infusion Way
  • Micro volume series dual-piston
  • Infusion pressure
  • 0 - 9999 Psi
Standard HPLC : HPLC system LHLC-B10
  • High pressure pump
  • High pressure gradient pump
  • Peak operating pressure
  • 45 MPa, Stainless steel pump
  • Pressure
  • ± 0.02 MPa

Analytical HPLC

Labtron Analytical HPLC measures compounds in mixtures using column and detector system. They have deuterium and tungsten lamps that work together for both flexible and accurate detection. Measurement can be performed with three different methods for precise analysis. The system offers control via panel or computer for easy parameter and pump management. Our Analytical HPLC ideal for precise separation, identification, and quantification of compounds in various samples.

Analytical HPLC : Analytical HPLC-A7840
  • Pump Specifications
  • Double plunger series mode, floating plunger design, single stroke volume 30 µl
  • Detector Specifications
  • 190 to 700 nm
Analytical HPLC : Analytical HPLC-A7835
  • Pump Specifications
  • HPP-B1
  • Detector Specifications
  • HPD-B2
Analytical HPLC : Analytical HPLC-A7832
  • Detector Specifications
  • Model No HPD-A20 HPD-A21 Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm ) Wavelength accuracy ± 0.5 nm ± 2 nm Wavelength repeatability 0.15 nm 0.3 nm Band width 8 nm 8 nm Optical path 10 nm 10 nm Deuterium lamp 190 to 400 nm 190 to 400 nm Tungsten lamp 400 to 800 nm 400 to 800 nm Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5 Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4 Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8 Power 100 W 100 W Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm Weight 9.5 kg 9.5 kg
  • Pump Specifications
  • 0.0001 to 10 ml / min
Analytical HPLC : Analytical HPLC System LAHS-A10
  • Pump specification
  • Quaternary Low Pressure Pump
  • UV/VIS Detector
  • 190 to 800 nm
  • Data-processing Workstation
  • System contain the tables for regular samples Equipped with Internal and external standard calculation process Automatic display, print, export of data and starting of another program on completion on measurement Observe with the condition of 21 CFR part 11 directive of the FDA