Analytical HPLC : Analytical HPLC-A7832


Share :



Analytical HPLC-A7832 system is equipped with a flow rate range of 0.0001 to 10 ml per minute. Integrated with a single and dual wavelength UV-Vis detector with a range of 190 to 800 nm that analyzes sample’s absorption at different wavelengths and a high pressure pump providing continuous consistent flow. Built in column heater provides reproducible retention time.



Available Range :

Detector Specifications :
Model No HPD-A20 HPD-A21
Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm )
Wavelength accuracy ± 0.5 nm ± 2 nm
Wavelength repeatability 0.15 nm 0.3 nm
Band width 8 nm 8 nm
Optical path 10 nm 10 nm
Deuterium lamp 190 to 400 nm 190 to 400 nm
Tungsten lamp 400 to 800 nm 400 to 800 nm
Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5
Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4
Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8
Power 100 W 100 W
Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz
Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm
Weight 9.5 kg 9.5 kg
Pump Specifications : Model No : HPP-B1 Detector Specifications : Model No : HPD-B2 Pump specification : Type : Quaternary Low Pressure Pump UV/VIS Detector : Wavelength Range : 190 to 800 nm Data-processing Workstation : System contain the tables for regular samples
Equipped with Internal and external standard calculation process
Automatic display, print, export of data and starting of another program on completion on measurement
Observe with the condition of 21 CFR part 11 directive of the FDA
High Pressure Constant Flow Pump : Double plunger reciprocating pump : 1 set UV/Visible Detector : Wavelength range : 190 to 700 nm High Pressure Constant Flow Pump : Double plunger reciprocating pump : 2 sets UV/Visible Detector : Wavelength range : 190 to 700 nm Pump Specifications : Solvent delivery : Double plunger series mode, floating plunger design, single stroke volume 30 µl Detector Specifications : Wavelength range : 190 to 700 nm
Detector Specifications
Model No HPD-A20 HPD-A21
Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm )
Wavelength accuracy ± 0.5 nm ± 2 nm
Wavelength repeatability 0.15 nm 0.3 nm
Band width 8 nm 8 nm
Optical path 10 nm 10 nm
Deuterium lamp 190 to 400 nm 190 to 400 nm
Tungsten lamp 400 to 800 nm 400 to 800 nm
Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5
Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4
Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8
Power 100 W 100 W
Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz
Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm
Weight 9.5 kg 9.5 kg
Pump Specifications
Flow rate range0.0001 to 10 ml / min
Maximum pressure50 MPa , 0 to 2 ml / min
Column size4.6 × 250 mm
Sample size5 µm
Pressure pulsation≤ 1 % at 10 MPa
Flow rate accuracy± 0.15 % at 1 ml / min
Flow rate repeatability %≤ 0.1
Gradient accuracy %± 1.5
Gradient repeatability %≤ 0.2
Dimension460 × 310 × 180 mm
Power supply90 V
Weight11.6 kg
  • Compression compensation ensuring gradient repeatability
  • Low pressure gradient
  • Detector ( Deuterium or tungsten lamp )
  • Automatic sample injector ( Autosampler )
  • 10 point calibration pump for linear pressure control
  • Error alarm function for over pressure ,under pressure and leakage
Used in pharmaceutical analysis, food nutrient analysis of amino acids and sugars, detection of food contaminants, environmental pollutant and chemical product purity analysis
Accessory Quantity
Pump 2
UV-Vis detector ( without flow cell ) 1
Analytical flow cell 1
Injection valve 1
20 μl sample loop 1
4.6 × 250 mm ( 5 µm ) analytical column 1
Solvent tray 1
Binary gradient kit 1
Mixing chamber 1
Accessory Quantity
Autosampler 1
Fraction collector 1
Column oven 1

Standard HPLC

Labtron Standard HPLC analyze complex mixtures efficiently and provides valuable data for both qualitative and quantitative analysis. They achieve high resolution with fine column packing and optimized flow rates. Their high-pressure pump offers precise mixing, sleek design and easy operation. The UV detector includes dual-beam monochromator, light battery, and deuterium lamp for accuracy. Our Standard HPLC is essential for precise compound analysis in pharmaceuticals, food, environmental studies, biotechnology, and forensics.

Standard HPLC : HPLC system LHLC-A10
  • High pressure pump
  • Single pump
  • Flow rate range
  • 0.001 - 9.999 mL / min (0.001 mL / min increment)
  • Pressure range
  • ≤ 0.5 MPa (0 - 42 MPa)
Standard HPLC : HPLC system LHLC-A11
  • High pressure pump
  • Two sets of pump
  • Flow rate range
  • 0.001 - 9.999 mL / min (0.001 mL / min increments)
  • Pressure range
  • ≤ 0.5 MPa (0 - 42 MPa)
Standard HPLC : HPLC system LHLC-B11
  • High pressure pump
  • High pressure constant-current infusion pump
  • Infusion Way
  • Micro volume series dual-piston
  • Infusion pressure
  • 0 - 9999 Psi
Standard HPLC : HPLC system LHLC-B10
  • High pressure pump
  • High pressure gradient pump
  • Peak operating pressure
  • 45 MPa, Stainless steel pump
  • Pressure
  • ± 0.02 MPa

Analytical HPLC

Labtron Analytical HPLC measures compounds in mixtures using column and detector system. They have deuterium and tungsten lamps that work together for both flexible and accurate detection. Measurement can be performed with three different methods for precise analysis. The system offers control via panel or computer for easy parameter and pump management. Our Analytical HPLC ideal for precise separation, identification, and quantification of compounds in various samples.

Analytical HPLC : Analytical HPLC-A7840
  • Pump Specifications
  • Double plunger series mode, floating plunger design, single stroke volume 30 µl
  • Detector Specifications
  • 190 to 700 nm
Analytical HPLC : Analytical HPLC-A7835
  • Pump Specifications
  • HPP-B1
  • Detector Specifications
  • HPD-B2
Analytical HPLC : Analytical HPLC System LAHS-A10
  • Pump specification
  • Quaternary Low Pressure Pump
  • UV/VIS Detector
  • 190 to 800 nm
  • Data-processing Workstation
  • System contain the tables for regular samples Equipped with Internal and external standard calculation process Automatic display, print, export of data and starting of another program on completion on measurement Observe with the condition of 21 CFR part 11 directive of the FDA
Analytical HPLC : Analytical HPLC System LAHS-B10
  • High Pressure Constant Flow Pump
  • 1 set
  • UV/Visible Detector
  • 190 to 700 nm