Paper Testing Instruments : Coefficient of friction tester TP-D10


Share :



Coefficient of friction tester TP-D10 is used in testing the static & kinetic friction coefficient of plastic films and sheet. Tester is designed in accordance with ISO 8295 standard. It is supported by professional software to print single or group results, reports and curves automatically.



Available Range :

Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm Sample (size) length : 38×70 mm Sample (size) length : 90 to 200 mm Sample (size) length : 180 mm (180, 150, 100, 90, 50 mm adjustable) Sample (size) length : 0 to 200 mm adjustable
Measurement range0.01 to 10 N
Slider weight200 g
Slider size63×63 mm
Testing accuracy± 2 %
Dimension of working plate170×225 mm
Speed of slider100 ± 1 0mm/min
Slider strokeMax 100 mm (adjustable)
  • Microprocessor controlled computer system
  • Equipped with build-in mini printer
  • Quick start options for staring new test
  • Simultaneously measures kinetic & static coefficients of friction
  • LCD screen display
  • Easy to use
Coefficient of friction tester is used to test kinetic and static coefficient of friction samples, materials used in paper & cardboard industry.

Paper Testing Instruments

Paper Testing Instruments : Whiteness and chromaticity tester TP-A10
  • Sample (size) length
  • Diameter ≥30 mm, Thickness ≤ 40 mm
  • Measurement mode
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
  • Stability
  • ≤ 0.1 within 30 min
Paper Testing Instruments : Whiteness meter TP-A11
  • Sample (size) length
  • Diameter ≥30 mm, Thickness ≤ 40 mm
  • System
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
  • Light source
  • D65 as illuminating source
Paper Testing Instruments : Tensile Stiffness Tester TP-B10
  • Sample (size) length
  • 38×70 mm
  • Measuring range
  • (1-500) mN.m (divided into 7 small ranges)
  • Indication error
  • 0.02
Paper Testing Instruments : Automatic horizontal tensile tester TP-B11
  • Sample (size) length
  • 90 to 200 mm
  • Sample width
  • 15 mm, 25 mm, 50mm
  • Measuring range
  • 0 to 30, 0 to 100 N,0 to 300 N

Plastic Testing Instruments

Plastic Testing Instruments : Vicat softening temperature & HDT machine TVHT-A10
  • Operating temperature
  • Ambient temperature to 300°C
  • Heating rate
  • 50°C/ h (5 ± 0.5°C/ 6 min) , 120°C/ h (12 ± 1°C/ 6 min)
  • Maximum temp. error with heating speed
  • ± 5°C under 50°C/ h, ± 1°C under 120°C/ h
Plastic Testing Instruments : Primary adhesive tester TPAT-A10
  • Inclined adjustable angle
  • 0 to 40°
  • Panel width
  • 120 mm
  • Test area width
  • 80 mm
Plastic Testing Instruments : Melt flow Indexer TMFI-A10
  • Measuring range
  • 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)
  • Measuring rate
  • 0.001 S
  • Temperature range
  • 50 to 400°C
Plastic Testing Instruments : Melt flow Indexer TMFI-A11
  • Measuring range
  • 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)
  • Measuring rate
  • 0.001 S
  • Temperature range
  • 50 to 400°C

Rubber Testing Instruments

Rubber Testing Instruments : DIN abrasion tester TDAT-A10
  • Test arm weight
  • 2.5 N
  • Additional Loads
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
  • Idler
  • 150 mm
Rubber Testing Instruments : Mooney viscometer TMV-A10
  • Control temperature range
  • Normal temperature to 200°C
  • Temperature display resolution
  • 0.01°C
  • Temperature control accuracy
  • ± 0.3°
Rubber Testing Instruments : No rotor rheometer TNRR-A10
  • Temperature tester
  • Room temperature to 200°C
  • Temperature display resolution
  • 0.1°C
  • Temperature control accuracy
  • ≤ ± 0.3°C
Rubber Testing Instruments : Rubber low temperature brittleness tester TRBT-A10
  • Temperature range
  • -60°C to 0°C
  • Temperature accuracy
  • ± 0.5°C
  • Impact speed
  • 2 m/s ± 0.2 m/s

NDT Testing Instruments

NDT Testing Instruments : Rockwell hardness meter TRHM-A10
  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Total test force dwell time
  • 0 to 30 S
NDT Testing Instruments : Rockwell hardness meter TRHM-A11
  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Total test force dwell time
  • 1 to 30 S
NDT Testing Instruments : Rockwell hardness meter (motorized type) TRHM-B10
  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Brinell hardness test
  • 306, 613, 1839 N
NDT Testing Instruments : Digital low load Vickers Hardness tester TDVH-A10
  • Test force
  • 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
  • Hardness value symbol
  • HV1, HV5, HV10, HV20, HV30, HV250
  • Error range in display
  • ± 3.0 %, ± 2.0 %

Soil Testing Instruments

Soil Testing Instruments : Soil moisture meter TSMM-A10
  • Measurement range
  • 0 to 80 %
  • Resolution
  • 0.1
  • Accuracy
  • ± 2 % n (non-saturation condition)
Soil Testing Instruments : Soil moisture meter TSMM-A11
  • Measurement range
  • 0 to 90 %
  • Resolution
  • 0.1 or 0.01
  • Accuracy
  • ± 5 % n (non-saturation condition)
Soil Testing Instruments : Soil moisture meter TSMM-A12
  • Measurement range
  • 0 to 60 %
  • Resolution
  • 0.1
  • Accuracy
  • ± 5 % n (non-saturation condition)
Soil Testing Instruments : Soil Salinity tester TSST-A10
  • Salinity Measurement range
  • 0.00 to 19.99 ms/cm
  • Measuring accuracy
  • EC ± 2% full scale
  • Temperature Measurement range
  • -5 to 50°C