Plastic Testing Instruments : Primary adhesive tester TPAT-A10


Share :



Primary adhesive tester TPAT-A10 is based on principles of inclined surface rolling ball tack method to form a bond with surface of another material upon brief contact under virtually no pressure. It is widely used in paper & plastic industry for packaging & other purpose. The adjustable inclined angle of this adhesive tester, can be adjusted freely to meets requirements of the users.



Available Range :

The maximum temperature : 300°C Impact Speed & Energy (charpy) : 2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25J Measuring range : 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density) Measuring range : 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density) Vacuum degree : 0 to 90 KPa Resolution : 0.1 % O2
Inclined adjustable angle0 to 40°
Panel width120 mm
Test area width80 mm
Standard steel balls1/32 to 1 inch
Dimension (L*W*H)320×140×180 mm
Net weight6 kg
  • Designed is in accordance with rolling ball method
  • Adjustable inclined angle range 0 to 40°
  • Superior steel balls design
  • Easy to operate
Primary Adhesive Tester has applications in adhesive tests of pressure sensitive tapes, bandages, plaster, label, films & other products.

Paper Testing Instruments

Paper Testing Instruments : Whiteness and chromaticity tester TP-A10
  • Sample (size) length
  • Diameter ≥30 mm, Thickness ≤ 40 mm
  • Measurement mode
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
  • Stability
  • ≤ 0.1 within 30 min
Paper Testing Instruments : Whiteness meter TP-A11
  • Sample (size) length
  • Diameter ≥30 mm, Thickness ≤ 40 mm
  • System
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
  • Light source
  • D65 as illuminating source
Paper Testing Instruments : Tensile Stiffness Tester TP-B10
  • Sample (size) length
  • 38×70 mm
  • Measuring range
  • (1-500) mN.m (divided into 7 small ranges)
  • Indication error
  • 0.02
Paper Testing Instruments : Automatic horizontal tensile tester TP-B11
  • Sample (size) length
  • 90 to 200 mm
  • Sample width
  • 15 mm, 25 mm, 50mm
  • Measuring range
  • 0 to 30, 0 to 100 N,0 to 300 N

Plastic Testing Instruments

Plastic Testing Instruments : Vicat softening temperature & HDT machine TVHT-A10
  • Operating temperature
  • Ambient temperature to 300°C
  • Heating rate
  • 50°C/ h (5 ± 0.5°C/ 6 min) , 120°C/ h (12 ± 1°C/ 6 min)
  • Maximum temp. error with heating speed
  • ± 5°C under 50°C/ h, ± 1°C under 120°C/ h
Plastic Testing Instruments : Melt flow Indexer TMFI-A10
  • Measuring range
  • 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)
  • Measuring rate
  • 0.001 S
  • Temperature range
  • 50 to 400°C
Plastic Testing Instruments : Melt flow Indexer TMFI-A11
  • Measuring range
  • 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)
  • Measuring rate
  • 0.001 S
  • Temperature range
  • 50 to 400°C
Plastic Testing Instruments : Heat sealer THS-A10
  • Seal temperature
  • Room temperature -250°C
  • Control accuracy
  • ± 0.2°C
  • Dwell time
  • 0.1 S to 999.9 S

Rubber Testing Instruments

Rubber Testing Instruments : DIN abrasion tester TDAT-A10
  • Test arm weight
  • 2.5 N
  • Additional Loads
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
  • Idler
  • 150 mm
Rubber Testing Instruments : Mooney viscometer TMV-A10
  • Control temperature range
  • Normal temperature to 200°C
  • Temperature display resolution
  • 0.01°C
  • Temperature control accuracy
  • ± 0.3°
Rubber Testing Instruments : No rotor rheometer TNRR-A10
  • Temperature tester
  • Room temperature to 200°C
  • Temperature display resolution
  • 0.1°C
  • Temperature control accuracy
  • ≤ ± 0.3°C
Rubber Testing Instruments : Rubber low temperature brittleness tester TRBT-A10
  • Temperature range
  • -60°C to 0°C
  • Temperature accuracy
  • ± 0.5°C
  • Impact speed
  • 2 m/s ± 0.2 m/s

NDT Testing Instruments

NDT Testing Instruments : Rockwell hardness meter TRHM-A10
  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Total test force dwell time
  • 0 to 30 S
NDT Testing Instruments : Rockwell hardness meter TRHM-A11
  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Total test force dwell time
  • 1 to 30 S
NDT Testing Instruments : Rockwell hardness meter (motorized type) TRHM-B10
  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Brinell hardness test
  • 306, 613, 1839 N
NDT Testing Instruments : Digital low load Vickers Hardness tester TDVH-A10
  • Test force
  • 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
  • Hardness value symbol
  • HV1, HV5, HV10, HV20, HV30, HV250
  • Error range in display
  • ± 3.0 %, ± 2.0 %

Soil Testing Instruments

Soil Testing Instruments : Soil moisture meter TSMM-A10
  • Measurement range
  • 0 to 80 %
  • Resolution
  • 0.1
  • Accuracy
  • ± 2 % n (non-saturation condition)
Soil Testing Instruments : Soil moisture meter TSMM-A11
  • Measurement range
  • 0 to 90 %
  • Resolution
  • 0.1 or 0.01
  • Accuracy
  • ± 5 % n (non-saturation condition)
Soil Testing Instruments : Soil moisture meter TSMM-A12
  • Measurement range
  • 0 to 60 %
  • Resolution
  • 0.1
  • Accuracy
  • ± 5 % n (non-saturation condition)
Soil Testing Instruments : Soil Salinity tester TSST-A10
  • Salinity Measurement range
  • 0.00 to 19.99 ms/cm
  • Measuring accuracy
  • EC ± 2% full scale
  • Temperature Measurement range
  • -5 to 50°C