Mooney viscometer TMV-A10 is designed to measure the change in elastomers properties, viscosity, scorch time & cure rates of rubber & plastic. With strong data function, mooney viscometer supports storage, drawing and output of multiple curves under the same interface. The resistance to rotation from the elastomer is, its shearing viscosity proportional to mean absolute viscosity of the specimen.



Available Range :

Temperature tester : Room temperature to 200°C Control temperature range : Normal temperature to 200°C Temperature range : -60°C to 0°C Test arm weight : 2.5 N Temperature range : RT 50° to 300° Mixed capacity : 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Control temperature rangeNormal temperature to 200°C
Temperature display resolution0.01°C
Temperature control accuracy± 0.3°
Calibration accuracyMooney value ± 0.5
Rotor speed2 rpm
Speed accuracy± 0.02 rpm
Torque rangeMooney value 0 to 200
Torque resolutionMooney value 0.1
Printer connectionYes
Content printedData, time, temperature, mooney scorch curve & MV , T5 T35 T3 T18 @15 @30
Power supplyAC 220 V, 50 Hz, ± 10 %
  • PID microprocessor controlled technology
  • Servo-driven motor for up to 0.5 % accuracy
  • Store and modify the past test reports
  • Measures the strength of rubber from characteristic curve and data
  • Tests standard curve setting, statics, deviation setting, CPK calculations
  • Supports data interface query in multiple forms
  • Multiple analysis functions
The Mooney viscometer is used in rubber & plastic industry for quality & research testing of elastomers, polymers.

Paper Testing Instruments

Paper Testing Instruments : Whiteness and chromaticity tester TP-A10
  • Sample (size) length
  • Diameter ≥30 mm, Thickness ≤ 40 mm
  • Measurement mode
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
  • Stability
  • ≤ 0.1 within 30 min
Paper Testing Instruments : Whiteness meter TP-A11
  • Sample (size) length
  • Diameter ≥30 mm, Thickness ≤ 40 mm
  • System
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
  • Light source
  • D65 as illuminating source
Paper Testing Instruments : Tensile Stiffness Tester TP-B10
  • Sample (size) length
  • 38×70 mm
  • Measuring range
  • (1-500) mN.m (divided into 7 small ranges)
  • Indication error
  • 0.02
Paper Testing Instruments : Automatic horizontal tensile tester TP-B11
  • Sample (size) length
  • 90 to 200 mm
  • Sample width
  • 15 mm, 25 mm, 50mm
  • Measuring range
  • 0 to 30, 0 to 100 N,0 to 300 N

Plastic Testing Instruments

Plastic Testing Instruments : Vicat softening temperature & HDT machine TVHT-A10
  • Operating temperature
  • Ambient temperature to 300°C
  • Heating rate
  • 50°C/ h (5 ± 0.5°C/ 6 min) , 120°C/ h (12 ± 1°C/ 6 min)
  • Maximum temp. error with heating speed
  • ± 5°C under 50°C/ h, ± 1°C under 120°C/ h
Plastic Testing Instruments : Primary adhesive tester TPAT-A10
  • Inclined adjustable angle
  • 0 to 40°
  • Panel width
  • 120 mm
  • Test area width
  • 80 mm
Plastic Testing Instruments : Melt flow Indexer TMFI-A10
  • Measuring range
  • 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)
  • Measuring rate
  • 0.001 S
  • Temperature range
  • 50 to 400°C
Plastic Testing Instruments : Melt flow Indexer TMFI-A11
  • Measuring range
  • 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)
  • Measuring rate
  • 0.001 S
  • Temperature range
  • 50 to 400°C

Rubber Testing Instruments

Rubber Testing Instruments : DIN abrasion tester TDAT-A10
  • Test arm weight
  • 2.5 N
  • Additional Loads
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
  • Idler
  • 150 mm
Rubber Testing Instruments : No rotor rheometer TNRR-A10
  • Temperature tester
  • Room temperature to 200°C
  • Temperature display resolution
  • 0.1°C
  • Temperature control accuracy
  • ≤ ± 0.3°C
Rubber Testing Instruments : Rubber low temperature brittleness tester TRBT-A10
  • Temperature range
  • -60°C to 0°C
  • Temperature accuracy
  • ± 0.5°C
  • Impact speed
  • 2 m/s ± 0.2 m/s
Rubber Testing Instruments : Rubber-weiss plasticity testing machine TRWM-A10
  • Temperature range
  • RT 50° to 300°
  • Temperature accuracy
  • ± 1°
  • Measuring range
  • 0.01 to 25 mm

NDT Testing Instruments

NDT Testing Instruments : Rockwell hardness meter TRHM-A10
  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Total test force dwell time
  • 0 to 30 S
NDT Testing Instruments : Rockwell hardness meter TRHM-A11
  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Total test force dwell time
  • 1 to 30 S
NDT Testing Instruments : Rockwell hardness meter (motorized type) TRHM-B10
  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Brinell hardness test
  • 306, 613, 1839 N
NDT Testing Instruments : Digital low load Vickers Hardness tester TDVH-A10
  • Test force
  • 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
  • Hardness value symbol
  • HV1, HV5, HV10, HV20, HV30, HV250
  • Error range in display
  • ± 3.0 %, ± 2.0 %

Soil Testing Instruments

Soil Testing Instruments : Soil moisture meter TSMM-A10
  • Measurement range
  • 0 to 80 %
  • Resolution
  • 0.1
  • Accuracy
  • ± 2 % n (non-saturation condition)
Soil Testing Instruments : Soil moisture meter TSMM-A11
  • Measurement range
  • 0 to 90 %
  • Resolution
  • 0.1 or 0.01
  • Accuracy
  • ± 5 % n (non-saturation condition)
Soil Testing Instruments : Soil moisture meter TSMM-A12
  • Measurement range
  • 0 to 60 %
  • Resolution
  • 0.1
  • Accuracy
  • ± 5 % n (non-saturation condition)
Soil Testing Instruments : Soil Salinity tester TSST-A10
  • Salinity Measurement range
  • 0.00 to 19.99 ms/cm
  • Measuring accuracy
  • EC ± 2% full scale
  • Temperature Measurement range
  • -5 to 50°C