pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C
TDS Mode
TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS Accuracy ± 1 % F.S.
TDS Factor 0.1  to 1.0 (default 0.5)
Temperature Range0 to 105°C, 32 to 221°F
Temperature Accuracy± 0.5°C
Temperature Resolution0.1°C
Temperature Calibrations Points1 Point
Temperature Compensation ModeManual or Automatic
Data Hold FunctionManual or Automatic Endpoint Detection
Stability CriteriaLow or High
Calibration Due Alarm1 to 31 Days
Reset FunctionYes
MemoryStores Up to 500 data sets
OutputUSB interface
ConnectorBNC, 6-pin mini plug
DisplayLCD
Power supplyDC5 V, AC 220 V, 50 Hz
Dimension (L × W × H)210 × 188 × 60 mm
Weight1.5 kg
  • Common Features
  • Stability indicator displays the status of current measurement
  • Auto hold function freezes stable, final readings for better viewing and recording
  • Manual temperature calibration to rectify the deviations in temperature
  • Automatic temperature compensation for accurate measured value over the entire range
  • Selectable temperature units (°C or °F) for different application requirements
  • Expanded memory stores and recalls up to 500 readings
  • Help message as an operational guide, helps users for quick access to the parameters
  • Reset function automatically resumes all the setting back to factory default options
  • Store data is transferrable into computer via USB communication interface
  • pH mode
  • 1-5 points push button calibration to automatically identify pH buffer
  • Convenient to select pH buffer standard (USA/NIST/DIN) or custom
  • Automatic electrode slope display helps operator whether to replace the sensor
  • Conductivity/TDS mode
  • 1-5 point for calibration with automatically identification of calibration solutions
  • Can select cell constant (0.1/1/10) and normalization temperature (20°C or 25°C)
  • TDS conversion factor, seawater, practical salinity measurements mode to meet different water quality measurement requirements
  • Linear or pure water compensation improves the measurement accuracy
Used for quality checking of water on different parameters across research, QC labs, water management plants and others production units.
Accessories No. Name
1 pH Electrode (for general liquids)
2 Conductivity Electrode (for general liquids)
3 Temperature probe
4 pH Buffer pouches (pH 4.01/ 7.00/ 10.01)
5 Conductivity standard solutions (10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm)
6 USB cable
7 DC5 V power adapter
Accessories No. Name
1 Temperature probe
2 Calibration Solutions for pH and Conductivity
3 pH electrodes suitable for non-aqueous, high alkalinity, low conductivity, tis buffers, biofuels and others
4 Conductivity electrode suitable for Pure water, general applications, high conductivity liquids
5 DC5V power adapter