Visible Spectrophotometer : Vis Spectrophotometer LVS-A10


Share :



Visible spectrophotometer LVS-A10 offers 330 to 1000 nm wavelength range with single beam has 1200 lines/mm grating C-T monochromator optical system. It uses silicon photo diode detector and tungsten lamp as light source which provides the best wavelength coverage across the working range of the spectrophotometer. The Display screen show the concentration data. This highly accurate spectrophotometer is designed for industries and laboratories.



Available Range :

Wavelength Range : 330 to 1000 nm Wavelength Range : 335 ~ 1000 nm Wavelength Range : 325 ~ 1000 nm Wavelength Range : 320 ~ 1100 nm Wavelength Range : 320 ~ 1000 nm Wavelength range : 320 to 1100 nm
Wavelength Range330 to 1000 nm
Spectral Bandwidth5 nm
Wavelength Accuracy± 2 nm
Wavelength Repeatability≤ 1.0 nm
Photometric RangeT: 0 to199.9%, A: -0.3 to2.5 Abs, F; 0 to 9999, C: 0 to 9999
Photometric Accuracy± 0.5 % T
Photometric Repeatability≤ 0.2 % T
DetectorSilicone photo diode
Light Source20 W, 12 V Tungsten lamp
Stray Light≤ 0.5 % T (360 nm)
StabilityDark current: ≤ 0.2 % T, Light Current: ≤ 0.5 % T
Power Requirement220 V ± 20 V, 50 Hz ± 1 Hz
Dimensions470 × 350 × 200 mm
Weight8 kg
Optical SystemSingle beam, C-T grating monochromator 1200 lines/ mm
  • Wavelength range 330 to 1000 nm
  • Spectral bandwidth 5 nm
  • C-T grating monochromator 1200 lines/ mm
  • 20 W, 12 V Tungsten lamp as light source
  • 100 % Transmittance calibration
  • High accuracy with digital wavelength display
Visible spectrophotometer is used for quantitative and qualitative analysis, detection of impurities and functional groups determination etc. across biochemical, environmental, food, medical, petrochemical and other industry.

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV/Vis Spectrophotometer : Double Beam UV/Vis Spectrophotometer LUS-B16
  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 0.5 / 1.0 / 2.0 / 4.0 nm adjustable
Double Beam UV/Vis Spectrophotometer : Double beam UV-Visible Spectrophotometer LUS-B14
  • Wavelength range
  • 190 ~ 1100 nm
  • Spectral bandwidth
  • 1.8 nm
  • Wavelength accuracy
  • ± 0.3 nm
Double Beam UV/Vis Spectrophotometer : Double Beam UV/Vis Spectrophotometer LUS-B30
  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 2 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Double Beam UV/Vis Spectrophotometer : Double Beam UV/Vis Spectrophotometer LUS-B31
  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 1 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer : Nano Spectrophotometer LNS-A10
  • Wavelength range
  • 200 - 800 nm
  • Path length
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
  • Wavelength accuracy
  • ± 1 nm
Nano Spectrophotometer : Nano Spectrophotometer LNS-A21
  • Wavelength range
  • 200 - 850 nm
  • Path length
  • 1 mm, 2 mm, 5 mm, 10 mm
  • Wavelength accuracy
  • ± 1 nm
Nano Spectrophotometer : Nano Spectrophotometer LNS-B11
  • Wavelength range
  • 230 nm, 260 nm, 280 nm
  • Path length
  • 1.0 mm, 0.2 mm
  • Minimum Sample size
  • 0.3 - 2.0 µl
Nano Spectrophotometer : Nano Spectrophotometer LNS-C10
  • Cuvette
  • No
  • PC
  • Inbuilt
  • Wavelength range
  • 190 - 850 nm

Single Beam UV/Visible Spectrophotometer

We manufacture highly precise Single Beam UV/Visible Spectrophotometer with wavelength ranging from 190-1100 nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations.

Single Beam UV/Visible Spectrophotometer : Single Beam UV/Visible Spectrophotometer LUS-A10
  • Wavelength Range
  • 190 ~ 1100 nm
  • Spectral Bandwidth
  • 1 nm
  • Wavelength Accuracy
  • ± 0.3 nm
Single Beam UV/Visible Spectrophotometer : Single Beam UV/Visible Spectrophotometer LUS-A11
  • Wavelength Range
  • 190 ~ 1100 nm
  • Spectral Bandwidth
  • 1.8 nm
  • Wavelength Accuracy
  • ± 0.3 nm
Single Beam UV/Visible Spectrophotometer : Single Beam UV/Visible Spectrophotometer LUS-A20
  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 2 nm
Single Beam UV/Visible Spectrophotometer : Single Beam UV/Visible Spectrophotometer LUS-A21
  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 1.8 nm

Visible Spectrophotometer

Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.

Visible Spectrophotometer : Vis Spectrophotometer LVS-A11
  • Wavelength Range
  • 335 ~ 1000 nm
  • Spectral Bandwidth
  • 4 nm
  • Wavelength Accuracy
  • ± 2 nm
Visible Spectrophotometer : Vis Spectrophotometer LVS-B10
  • Wavelength Range
  • 325 ~ 1000 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 2 nm
Visible Spectrophotometer : Vis Spectrophotometer LVS-C10
  • Wavelength Range
  • 320 ~ 1100 nm
  • Spectral Bandwidth
  • 4 nm
  • Wavelength Accuracy
  • ± 0.5 nm
Visible Spectrophotometer : Vis Spectrophotometer LVS-C11
  • Wavelength Range
  • 320 ~ 1000 nm
  • Spectral Bandwidth
  • 2 nm
  • Wavelength Accuracy
  • ± 0.5 nm

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A11
  • Wavelength range
  • 190 - 900 nm
  • Spectral Bandwidth
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
  • Wavelength accuracy
  • ≤ ± 0.5 nm
Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A20
  • Wavelength range
  • 180 - 900 nm
  • Spectral Bandwidth
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
  • Wavelength accuracy
  • ≤ 0.15 nm
Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A21
  • Wavelength range
  • 180 – 900 nm
  • Spectral Bandwidth
  • 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)
  • Wavelength accuracy
  • ≤ 0.15 nm
Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A22
  • Wavelength range
  • 180 – 900 nm
  • Spectral Bandwidth
  • 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
  • Wavelength accuracy
  • ≤ 0.15 nm

Table Top Spectrophotometer

Table Top Spectrophotometer : Table top spectrophotometer LTS-A10
  • Illumination system
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED
Table Top Spectrophotometer : Table top spectrophotometer LTS-A11
  • Illumination system
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED
Table Top Spectrophotometer : Table top spectrophotometer LTS-A12
  • Illumination system
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 15.2 cm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED
Table Top Spectrophotometer : Table top spectrophotometer LTS-A13
  • Illumination system
  • d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED

Portable Spectrophotometer

Portable Spectrophotometer : Portable spectrophotometer LSP-A10
  • Illumination
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab
  • Sensor
  • Blue light enhanced sensor array
Portable Spectrophotometer : Portable spectrophotometer LSP-A11
  • Illumination
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab Maximum:0.03
  • Sensor
  • Dual light path sensor array
Portable Spectrophotometer : Portable spectrophotometer LSP-A12
  • Illumination
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab
  • Sensor
  • Photoelectric diode sensor
Portable Spectrophotometer : Portable spectrophotometer LSP-A13
  • Illumination
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab
  • Sensor
  • Photoelectric diode sensor

Fluorescence Spectrophotometer

Fluorescence Spectrophotometer : Fluorescence Spectrophotometer LFS-A10
  • Light source
  • 150 W Xenon lamp
  • Excitation wavelength
  • 200 nm to 900 nm
  • Emission wavelength
  • 200 nm to 900 nm
Fluorescence Spectrophotometer : Fluorescence Spectrophotometer LFS-A12
  • Light source
  • 150 W Xenon lamp
  • Excitation wavelength
  • 200 nm to 900 nm
  • Emission wavelength
  • 200 nm to 900 nm
Fluorescence Spectrophotometer : Fluorescence Spectrophotometer LFS-A11
  • Excitation Source
  • 150 W Xenon Lamp
  • Excitation Wavelength
  • 200 nm to 900 nm
  • Excitation Slit
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nm

Xenon Lamp Spectrophotometer

Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A10
  • Optical system
  • Double Beam, Grating 1200 lines/mm
  • Wavelength Range
  • 190 nm to 1100 nm
  • Spectral Bandwidth
  • 2 nm
Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A11
  • Optical system
  • Double Beam, Grating 1200 lines/mm
  • Wavelength Range
  • 190 nm to 1100 nm
  • Spectral Bandwidth
  • 1 nm
Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A13
  • Optical system
  • Double Beam, Grating 1200 lines/mm
  • Wavelength Range
  • 190 nm to 1100 nm
  • Spectral Bandwidth
  • 2 nm
Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A14
  • Optical system
  • Double Beam, Grating 1200 lines/mm
  • Wavelength Range
  • 190 nm to 1100 nm
  • Spectral Bandwidth
  • 1 nm