Autoclaves | Vertical Autoclave LVA-A10

Vertical Autoclave LVA-A10 is top loading vertical pressure steam sterilizer with chamber capacity of 35 L, working sterilization temperature and pressure of 134°C and 0.22 MPa respectively. Designed with four wheels (castors) at base for easy movement of the unit. The standard 02 pcs of stainless steel baskets to keep the sterilization material load. The chamber is constructed of long lasting 304 grade stainless steel with superior corrosion resistance property. The vertical autoclave units is equipped with dual scale numerical pressure gauge to indicate temperature and pressure of the system. It works on electric heating or direct heating by immersing copper tubes of heating elements

Capacity 35 L
Chamber Volume 318×450 mm
Working Sterilization Temperature 134°C
Working Sterilization Pressure 0.22 MPa
Time Range 0 to 60 mins
Maximum Working Pressure 0.23 MPa
Sterilization Temperature Range 105 to 134°C
Heat Average ≤ ± 1°C
Power Consumption 2.5 kW
Power supply AC 220 V, 50 Hz
Overall Dimension 480×460×850 mm
Packing Dimension 570×550×970 mm
Net weight 42 kg
Gross weight 56 kg
  • Top loading sterilizing unit, whole body constructed of Stainless steel
  • Door design (with lock) adopted with silicone rubber seal to prevent steam leakage
  • Automatically shut off with beep alarm after sterilization
  • Manual water loading system
  • Casters for easy movement of whole unit
  • Double scale indication pressure gauge
  • Provision to set sterilization time and temperature with the help of knobs
  • Indicator light to indicate working status of the sterilization process, provide auto protection against over temperature, over pressure
  • Safe, reliable and user-friendly operation mode
  • Two stainless steel sterilizing baskets for loading material for sterilization
  • Equipped with safety valve, electronic circuit safety system, emergency exhaust switch
  • Complies with international standards
Vertical autoclave used in pharmaceutical industry, medicine and health care industry, Biotechnology, Microbiology for effective sterilization of glassware’s, biological materials, culture media and others.

Vertical Autoclave

Labtron Vertical autoclaves are manufactured keeping in mind the client’s requirements in research laboratories, hospitals & clinics and food & beverage sectors. These units are equipped with dual scale numerical pressure gauge to indicate temperature and pressure of the system.

Vertical Laboratory Autoclave LVA-G13

Vertical Laboratory Autoclave LVA-G13

  • Capacity
  • 100L
  • Sterilization Temperature
  • 134 °C
  • Sterilization Pressure
  • 0.22 Mpa
Vertical Laboratory Autoclave LVA-J12

Vertical Laboratory Autoclave LVA-J12

  • Capacity
  • 75 L
  • Sterilization Temperature
  • 115 to 129 °C
  • Sterilization Pressure
  • 0.165 MPa
Vertical Autoclave LVA-L11

Vertical Autoclave LVA-L11

  • Capacity
  • 85 L
  • Number of baskets
  • 2
  • Sterilization temperature
  • 105 °C to 138 °C
Vertical Autoclave LVA-B10

Vertical Autoclave LVA-B10

  • Capacity
  • 35 L
  • Chamber volume
  • 318 × 450 mm
  • Working Temperature
  • 134℃

Table Top Autoclave

We deliver a wide range of Table Top autoclaves with user-friendly operating system and a capacity ranging from 20L to 50L. These are highly accurate, reliable and in compliance with Class N European Standards.

Tabletop Laboratory Autoclave LTTA-A12

Tabletop Laboratory Autoclave LTTA-A12

  • Capacity
  • 35 L
  • Sterilization Temperature
  • 134 °C
  • Adjustment temperature
  • 105 to 134 °C
Tabletop Laboratory Autoclave LTTA-B13

Tabletop Laboratory Autoclave LTTA-B13

  • Capacity
  • 50 L
  • Sterilization Temperature
  • 105 °C - 134 °C
  • Sterilization Pressure
  • 0.22 MPa
Tabletop Laboratory Autoclave LTTA-A10

Tabletop Laboratory Autoclave LTTA-A10

  • Capacity
  • 20 L
  • Sterilization Temperature
  • 134 °C
  • Adjustment temperature
  • 105 to 134 °C
Tabletop Laboratory Autoclave LTTA-B12

Tabletop Laboratory Autoclave LTTA-B12

  • Capacity
  • 35 L
  • Sterilization Temperature
  • 105 °C - 134 °C
  • Sterilization Pressure
  • 0.22 MPa

Horizontal Autoclave

Horizontal autoclaves manufactured by us are designed with two pressure gauges to indicate inner and interlayer pressure with interlock device for safety. These units are composed of corrosion resistant stainless steel and equipped with silicon rubber to prevent steam leakage.

Horizontal Laboratory Autoclave LHA-E10

Horizontal Laboratory Autoclave LHA-E10

  • Capacity
  • 150 L
  • Sterilization Temperature
  • 134 °C
  • Sterilization Pressure
  • 0.22 MPa
Horizontal Laboratory Autoclave LHA-B10

Horizontal Laboratory Autoclave LHA-B10

  • Capacity
  • 150 L
  • Sterilization Temperature
  • 134 °C
  • Sterilization Pressure
  • 0.22 MPa
Horizontal Autoclave LHA-I10

Horizontal Autoclave LHA-I10

  • Capacity
  • 60 L
  • Design Temperature
  • 150°C
  • Design Pressure
  • 0.26 MPa
Horizontal Laboratory Autoclave LHA-E11

Horizontal Laboratory Autoclave LHA-E11

  • Capacity
  • 200 L
  • Sterilization Temperature
  • 134 °C
  • Sterilization Pressure
  • 0.22 MPa

Medical Autoclave

We offer Medical autoclave with user-friendly features which will not only sterilize the medical tools but can also be used for sterilizing medical waste prior to disposal with respect to the standards of municipal solid waste management.

Medical Autoclave LMA-A10

Medical Autoclave LMA-A10

  • Capacity
  • 14 L
  • Sterilization Time
  • 4 - 18 mins
  • Sterilization Temperature
  • 121 °C / 134 °C
Medical Autoclave LMA-C11

Medical Autoclave LMA-C11

  • Capacity
  • 17L
  • Sterilization Time
  • 4 - 20 mins
  • Sterilization Temperature
  • 121 °C / 134 °C
Medical Autoclave LMA-A11

Medical Autoclave LMA-A11

  • Capacity
  • 17 L
  • Sterilization Time
  • 4 - 18 mins
  • Sterilization Temperature
  • 121 °C / 134 °C
Medical Autoclave LMA-A20

Medical Autoclave LMA-A20

  • Type
  • B-type; Table-top
  • Capacity
  • 23 L
  • Sterilization temperature
  • 134°C

Plasma Autoclave

Plasma autoclave LPA-B10

Plasma autoclave LPA-B10

  • Chamber Volume
  • 100 L
  • Sterilization temperature
  • 50 ± 5°C
  • Working pressure
  • -50 Pa
Plasma Autoclave LPA-A10

Plasma Autoclave LPA-A10

  • Capacity
  • 80 L
  • Door type
  • Rectangular, single door
  • Chamber material
  • Anti rust aluminum alloy
Plasma autoclave LPA-B12

Plasma autoclave LPA-B12

  • Chamber Volume
  • 220 L
  • Sterilization temperature
  • 50 ± 5°C
  • Working pressure
  • -50 Pa
Plasma autoclave LPA-B11

Plasma autoclave LPA-B11

  • Chamber Volume
  • 130 L
  • Sterilization temperature
  • 50 ± 5°C
  • Working pressure
  • -50 Pa