Analytical HPLC-A7835
Analytical HPLC-A7835 system is equipped with a flow rate range of 0.0001 to 10 ml per minute. Integrated with a single and dual wavelength UV-Vis detector with a range of 190 to 800 nm that analyzes sample’s absorption at different wavelengths and a high pressure pump providing continuous consistent flow. Built in column heater provides reproducible retention time.
| Pump Specifications | <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Model No</strong></td><td>HPP-B1</td></tr><tr><td><strong>Flow rate range</strong></td><td>0.0001 to 10 ml / min</td></tr><tr><td><strong>Maximum pressure</strong></td><td>42 MPa , 0 to 5 ml / min</td></tr><tr><td><strong>Column size</strong></td><td>4.6 × 250 mm</td></tr><tr><td><strong>Sample size</strong></td><td>5 μm</td></tr><tr><td><strong>Pressure pulsation</strong></td><td>≤ 1.5 % at 10 MPa</td></tr><tr><td><strong>Flow rate accuracy</strong></td><td>± 0.2 % at 1 ml / min</td></tr><tr><td><strong>Flow rate repeatability %</strong></td><td>≤ 0.15</td></tr><tr><td><strong>Gradient accuracy %</strong></td><td>± 2</td></tr><tr><td><strong>Gradient repeatability %</strong></td><td>≤ 0.2</td></tr><tr><td><strong>Dimension</strong></td><td>450 × 260 × 190 mm</td></tr><tr><td><strong>Power supply</strong></td><td>90 V to 240 V</td></tr><tr><td><strong>Weight</strong></td><td>11.2 kg</td></tr></table> |
| Detector Specifications | <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Model No</strong></td><td>HPD-B2</td></tr><tr><td><strong>Wavelength range</strong></td><td>190 to 800 nm</td></tr><tr><td><strong>Wavelength accuracy</strong></td><td>± 0.75 nm</td></tr><tr><td><strong>Wavelength repeatability</strong></td><td>0.2 nm</td></tr><tr><td><strong>Band width</strong></td><td>8 nm</td></tr><tr><td><strong>Optical path</strong></td><td>10 nm</td></tr><tr><td><strong>Deuterium lamp</strong></td><td>190 to 400 nm</td></tr><tr><td><strong>Tungsten lamp</strong></td><td>400 to 800 nm</td></tr><tr><td><strong>Baseline noise ( Static ) Au</strong></td><td>≤ ± 0.5 × 10 <sup>-5</sup></td></tr><tr><td><strong>Baseline drift ( Static ) Au / h</strong></td><td>≤ 1.5 x 10 <sup>-4</sup></td></tr><tr><td><strong>Minimum detection limit</strong></td><td>≤ 4 x 10 <sup>-8</sup></td></tr><tr><td><strong>Power</strong></td><td>100 W</td></tr><tr><td><strong>Power supply</strong></td><td>90 V / 50 to 60 Hz</td></tr><tr><td><strong>Dimension</strong></td><td>460 × 260 × 190 mm</td></tr><tr><td><strong>Weight</strong></td><td>9.2 kg</td></tr></table> |
Used in pharmaceutical analysis, food nutrient analysis of amino acids and sugars, detection of food contaminants, environmental pollutant and chemical product purity analysis
www.labtron.co
Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER, United Kingdom
Email: info@labtron.co | Website: https://www.labtron.co/ | Phone: +44 2080 043 608