Benchtop Ion meter for Cl, LBIM-A10


Share :


Benchtop Ion meter for Cl, LBIM-A10


Benchtop Ion meter for Cl, LBIM-A10 comes with (Cl) chloride ion selective electrode for chloride ion concentration measurement. This Ion meter comes with ± 0.5 % F.S. measurement accuracy. The direct ion concentration readout helps in elaborate measurement process. The system menu allows setting the 8 parameters like calibration points, stability condition etc. It can measure concentration in ppm, mg / L, mol / L. The mV measurement is used to check the performance of ion selective electrode.



Available Range :

Ion measurement range : Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm Ion measurement range : F range: 1 × 106M – saturation, 0.02 ppm to saturation Ion measurement range : Na range: 1 × 105 - 1 M, 0.1 - 23000 ppm Ion measurement range : Ca range: 5 × 107 - 1 M, 0.02 - 4000 ppm Ion measurement range : Br range: 5 × 106 - 1 M, 0.4 - 79900 ppm Ion measurement range : NH4 range: 5 × 106 – 1 M, 0.1 – 18000 ppm
Ion measurement rangeCl range: 5 × 106 - 1 M, 1.8 - 35500 ppm
Ion measurement accuracy± 0.5 % F.S.
Resolution0.001, 0.01, 0.1, 1
Calibration points2 to 5 points
Calibration solutions0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
mV range(-1999.9) to 1999.9 mV
mV accuracy± 0.2 mV
mV resolution0.1 mV
Temperature measurement range0 to 105 °C, 32 to 221 °F
Temperature accuracy± 0.5 °C, ± 0.9 °F
Temperature resolution0.1°C
Temperature compensation0 to 100 °C, 32 to 212 °F
Compensation modeManual or automatic
Data hold functionManual or automatic endpoint detection
Reset functionYes
Stability conditionLow or high
Calibration due0 to 31 days
Power offManual or automatic (10,20,30 minutes)
MemoryStores up to 500 sets of data
OutputUSB communication interface
ConnectorBNC
DisplayLCD (130 × 110 mm)
PowerDC 5 V, using AC adapter, AC 220 V / 50 Hz
Dimension (L × W × H)210 × 188 × 60 mm
Weight1.5 kg
  • Large LCD display
  • 2 - 5 points calibration from low to high concentration
  • Direct ion concentration readout for elaborate measurement process
  • Selectable concentration units from ppm, mg / L, mol / L
  • mV measurements to check the performance of ion selective electrode
  • Temperature compensation provides accurate reading over the entire range
  • Stability indicator to show current measurement status
  • Calibration due reminder for regular calibration of the meter
  • Auto hold function to freeze stable reading for better viewing & recording
  • Automatic electrode diagnosis shows the slope of the sensor
  • Reset setting function
  • Expanded memory stores and recalls up to 500 readings
  • Built –in real time clock stamps
  • USB communication interface to transfer stored data to PC
Benchtop Ion meter is used to measure the chloride ion concentration present in potable water, D/W water, waste water and natural water resources using different ion concentration electrodes.
Cl chloride Ion selective electrode
Temperature probe
Standard solution (1000 ppm)
Ionic strength adjuster (30 mL)
USB cable
DC 5 V Power adapter
Ion selective electrode: CL range: 1.8 - 35500 ppm
Ion standard solutions: 480 mL / bottle
Ionic strength adjuster: 480 mL / bottle
Temperature probe with sensor