Benchtop conductivity meter LBCM-A11


Share :


Benchtop conductivity meter LBCM-A11


Benchtop conductivity meter LBCM-A11 is easy to use, it comes with 1 - 3 point calibration system for automatic recognition of the known calibration standards. The LCD display helps to view the measurements and set parameters. The temperature calibration by manual method improves the accuracy of conductivity meter. The system of conductivity meter can set up to 6 parameters like number of calibration points, cell constant etc.



Available Range :

Conductivity measurement range : 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm Conductivity measurement range : 0.000 μS/cm to 3000mS/cm Conductivity Mode : Conductivity measurement range : 0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm TDS Mode : TDS measurement Range : 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) Temperature Mode : Temperature range : 0 to 105°C, 32 to 221°F Cell constant : K=0.1, 1, 10
Conductivity measurement range0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
Conductivity accuracy± 1 % F.S.
Conductivity resolution0.01, 0.1, 1
Conductivity calibration solutions10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm
Conductivity calibration points1 - 3 points
Temperature compensation range & modeManual or automatic, 0 to 100 °C , 32 to 212 °F
Temperature range0 to 105 °C, 32 to 221 °F
Temperature accuracy± 1°
Temperature resolution0.1 °C
Temperature coefficient0.0 to 10.0 % per °C
Cell constantK= 0.1, 1, 10 or User-defined
Data hold functionManual or automatic
Connector6 - pin mini plug
DisplayLCD (315 × 75 mm)
PowerDC 6 V / 400 mA power adapter, AC 220 V / 50Hz
Dimension (L × W × H)210 × 205 × 75 mm
Weight1.5 kg
  • Equipped with white backlit LCD display
  • 1 - 3 point calibration with automatic recognition of calibration solution
  • Manual temperature compensation improves the measurement accuracy of meter
  • Automatic temperature compensation for accurate measured value over the entire range
  • Auto hold function freezes stable, final readings for better viewing and recording
  • Reset function automatically resumes all the settings to default mode
  • System menu allows setting the 6 parameters
  • Automatic power off helps to reduce battery power consumption
  • Help message as an operational guide for Quick access to the conductivity meter
The benchtop conductivity meter is used in water quality analysis, research, education, environmental monitoring, chemicals & liquids quality testing etc. for measuring conductivity.
Conductivity electrode
Temperature probe
DC 9 V power adapter
Conductivity electrode for pure water
Conductivity electrode for general liquids
Conductivity electrode for high conductivity
Conductivity standard solution 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm